Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41504
Title: Análise físico-química e bacteriológica da água de poços no distrito de Cachoeira, Pombal – PB.
Other Titles: Physicochemical and bacteriological analysis of well water in the district of Cachoeira, Pombal – PB.
???metadata.dc.creator???: ALMEIDA, Jonas Ferreira de.
???metadata.dc.contributor.advisor1???: PEREIRA JUNIOR, Ednaldo Barbosa.
???metadata.dc.contributor.referee1???: MOREIRA, Joserlan Nonato.
???metadata.dc.contributor.referee2???: SIQUEIRA, Eliezer da Cunha.
Keywords: Recursos hídricos;Águas subterrâneas;Coliformes fecais;Water resources;Groundwater;Fecal coliforms
Issue Date: 14-Jun-2023
Publisher: Universidade Federal de Campina Grande
Citation: ALMEIDA, Jonas Ferreira de. Análise físico-química e bacteriológica da água de poços no distrito de Cachoeira, Pombal – PB. 2023. 22 f. Artigo (Mestrado em Gestão e Sistemas Agroindustriais) - Centro de Ciências e Tecnologias Agroalimentar, Universidade Federal de Campina Grande, Pombal, Paraíba, Brasil, 2023.
???metadata.dc.description.resumo???: O estudo buscou analisar a qualidade da água dos poços do Distrito de Cachoeira, localizado na cidade de Pombal-PB, utilizando os parâmetros físicos, químicos e bacteriológicos, evidenciando possíveis riscos para a população que a consome. A pesquisa foi realizada inicialmente in loco, onde foram obtidas as amostras para posterior análise, logo após, estas foram levadas ao laboratório de solo e água do Instituto Federal de Educação, Ciência e Tecnologia da Paraíba – IFPB – Campus Sousa. Os valores referentes a temperatura foram obtidos ainda no local, utilizando-se um termômetro digital, os demais parâmetros foram analisados em laboratório. Para a condutividade elétrica foi utilizado o condutivimetro portátil digital, já o Ph foi analisado com o auxílio do pHgametro digital. Para obtenção dos valores de Na+ e K+, utilizou-se da fotometria de chama, as concentrações dos íons Ca++, Mg++, HCO3-e Cl-, foram evidenciadas pelo método de titulometria. A análise dos coliformes fecais e totais foi realizada através da utilização do substrato cromogênico. Todos os resultados foram comparados com os valores descritos na portaria MG/MS nº 888 de 4 de maio de 2021 e avaliados em triplicata para posteriormente ser efetuado o teste estatístico. Constatou-se que o poço P1 obteve resultados insatisfatórios nas concentrações de Cl- e SDT e que o poço P2 obteve resultados insatisfatórios na avaliação de Na+, Cl- e SDT, logo, ambos não atendem aos critérios descritos pela portaria em vigor. No mais, os poços P3, P4 e P5, apresentaram valores satisfatórios para todos os parâmetros físico-químicos propostos neste estudo, atendendo aos critérios de potabilidade estabelecidos. Todas as amostras analisadas obtiveram resultados satisfatórios também na análise dos coliformes fecais e totais, apresentando ausência de tais microrganismos em 100ml de água analisada, assim como descrito pela portaria em vigor. Diante dos dados obtidos ao fim do estudo, fica evidente que as amostras dos poços P1 e P2 apresentam parâmetros incompatíveis ao consumo humano, porém, podem ser destinadas a atividades domésticas. Em contrapartida, a água dos poços P3, P4 e P5 apresentam boa qualidade, estando em conformidade com os parâmetros avaliados e descritos pelo Ministério da Saúde, todavia, orienta-se a realização semestral de testes, para assegurar que não houve quaisquer tipos de contaminação, seja por químicos ou microrganismos.
Abstract: The study sought to analyze the quality of water from wells in the District of Cachoeira, located in the city of Pombal-PB, using physical, chemical and bacteriological parameters, highlighting possible risks for the population that consumes it. The research was initially carried out in loco, where samples were obtained for further analysis, soon after, these were taken to the soil and water laboratory of the Federal Institute of Education, Science and Technology of Paraíba – IFPB – Campus Sousa. Temperature values were obtained while still on site, using a digital thermometer, the other parameters were analyzed in the laboratory. For the electrical conductivity, a portable digital conductivity meter was used, while the Ph was analyzed with the aid of a digital pHgameter. To obtain Na+ and K+ values, flame photometry was used, the concentrations of Ca++, Mg++, HCO3- and Cl- ions were evidenced by the titration method. The analysis of fecal and total coliforms was performed using the chromogenic substrate. All results were compared with the values described in MG/MS Ordinance No. 888 of May 4, 2021 and evaluated in triplicate for later statistical testing. It was found that well P1 obtained unsatisfactory results in the concentrations of Cl- and TDS and that well P2 obtained unsatisfactory results in the evaluation of Na+, Cl- and TDS, therefore, both do not meet the criteria described by the ordinance in force. Furthermore, wells P3, P4 and P5 showed satisfactory values for all physical-chemical parameters proposed in this study, meeting the established potability criteria. All analyzed samples also obtained satisfactory results in the analysis of fecal and total coliforms, showing the absence of such microorganisms in 100ml of analyzed water, as described by the ordinance in force. Given the data obtained at the end of the study, it is evident that the samples from wells P1 and P2 have parameters incompatible with human consumption, however, they can be used for domestic activities. On the other hand, the water from wells P3, P4 and P5 are of good quality, in accordance with the parameters evaluated and described by the Ministry of Health, however, it is recommended that tests are carried out every six months to ensure that there has not been any type of contamination. , whether by chemicals or microorganisms.
Keywords: Recursos hídricos
Águas subterrâneas
Coliformes fecais
Water resources
Groundwater
Fecal coliforms
???metadata.dc.subject.cnpq???: Engenharia Sanitária
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41504
Appears in Collections:Mestrado Profissional em Sistemas Agroindustriais (Pombal).

Files in This Item:
File Description SizeFormat 
JONAS FERREIRA DE ALMEIDA- ARTIGO PPGGSA 2023.pdfJonas Ferreira de Almeida- Artigo PPGGSA 2023.276.42 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.