Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/4229
Full metadata record
DC FieldValueLanguage
dc.creator.IDSILVA, P. F.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/8146309314429987pt_BR
dc.contributor.advisor1DANTAS NETO, José.-
dc.contributor.advisor1IDDANTAS NETO, J.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/9137226205129315pt_BR
dc.contributor.referee1LIMA, Vera Lúcia Antunes de.-
dc.contributor.referee2SANTOS, Delfran Batista dos.-
dc.description.resumoA implantação de sistemas de irrigação eficientes torna-se uma necessidade nas regiões com escassez de água; assim, a utilização de águas de qualidade inferior é uma alternativa viável para irrigação garantindo seu bom funcionamento, fornecendo elementos para a operação do sistema. Objetivou-se, com o presente estudo, avaliar uniformidade de vazão em mangueira gotejadora autocompensante utilizando água de diferentes condutividades elétricas (CEa) num período de doze meses; especificamente, foram determinados os coeficientes de uniformidade de Christiansen (CUC) de distribuição (CUD), o estatístico (CUE), coeficiente de variação de fabricação (CVF), o grau de entupimento (GE), a eficiência de aplicação (EA), os gráficos individuais de Shewhart e o índice de capacidade do processo em gotejadores autocompensantes com águas de diferentes concentrações salinas. A pesquisa foi conduzida em casa de vegetação pertencente à Unidade Acadêmica de Engenharia Agrícola, Universidade Federal de Campina Grande, latitude 07º 13' S, longitude 35º 53' W e altitude média 550 m. Utilizou-se uma análise de variância em blocos inteiramente casualizados, no esquema fatorial com cinco níveis de condutividade elétrica da água (CEai) (0,6; 1,5; 2,5; 3,5 e 4,5 dS m-1 a 25° C ), sob quatro pressões de serviço (60, 100, 140 e 160 kPa), com três repetições, em dois cultivos consecutivos de girassol totalizando 60 parcelas experimentais. Para o controle estatístico de qualidade fixou-se a pressão de 160 kPa, em 15 ensaios de irrigação ao longo do experimento para emissores novos, com 210 e 350 horas de funcionamento. A variação de vazão dos emissores autocompensantes analisados foi considerada baixa ao longo do tempo dentro, portanto, da recomendação de ± 7% da vazão nominal. Os emissores obtiveram valores de exponente entre 0,02 a 0,09, considerados autocompensantes estando em conformidade com os dados do fabricante. A vazão que mais se aproximou da recomendada pelo fabricante em emissores novos ocorreu na pressão de 60 kPa e na salinidade de 0,6 dS m-1; quando se aumentou o tempo de funcionamento para 210 e 350 horas o comportamento foi semelhante ao dos emissores novos. Os valores encontrados dos coeficientes CUC, CUD, CUE, CVF, GE e EA, foram considerados excelentes mas não foram influenciados significativamente pelos níveis de sais da água de irrigação nem pela interação entre salinidade da água e pressão quando novos, sendo influenciados pela pressão de serviço aplicada. A interação entre (S x P) influenciou, de forma significativa, os coeficientes analisados para as avaliações realizadas com 210 e 350 horas de funcionamento, exceto para o CVq com 350 horas de funcionamento. O desempenho dos emissores foi considerado satisfatório utilizando-se água salina sendo a pressão de 60 kPa a que resultou na melhor relação custo/beneficio. Os gráficos de Shewhart são instrumentos capazes de diagnosticar alterações no sistema de irrigação, demonstrando o momento para se fazer sua manutenção. Os emissores foram considerados capazes quando novos; após 210 e 350 horas de funcionamento necessitam de manutenção para que possam continuar dentro dos limites de controle tornando o emissor capaz. O índice de capacidade do processo é uma ferramenta capaz de diagnosticar se o sistema de irrigação tem capacidade de se manter sob controle, ou seja, se será capaz de manter níveis aceitáveis de uniformidade, auxiliando o irrigante na tomada de decisão.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Tecnologia e Recursos Naturais - CTRNpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA AGRÍCOLApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Agrícolapt_BR
dc.subject.cnpqIrrigação e Drenagempt_BR
dc.titleUniformidade de vazão em mangueira gotejadora autocompensante utilizando água salina.pt_BR
dc.date.issued2014-02-24-
dc.description.abstractThe implementation of efficient irrigation systems becomes a necessity in regions where water is scarce, so the use of lower quality water is a viable alternative for irrigation besides evaluating its smooth operation, aiming at providing elements for system operation. The objective of this study was to evaluate uniformity of flow in self-compensating drip hose using different electrical conductivity (EC w) water in a twelve month period, specifically determined the coefficients Christiansen uniformity (CUC), distribution (CUD), statistical (CUE), coefficient of manufacturing variation (CVF), degree obstruction(GE), application efficiency (AE), individual Shewhart charts and process capability index in self- compensating drippers in waters of different salt concentrations. The research was conducted in a greenhouse belonging to the Academic Unit of Agricultural Engineering, Federal University of Campina Grande, latitude 07 º 13 'S, longitude 35 º 53' W and an average altitude 550 m. We used an analysis of variance in a completely randomized block with scheme factorial with five levels of electric conductivity (EC wi) (0.6, 1.5, 2.5, 3.5 and 4.5 dS m-1 a 25 ° C) end under four different operating pressures (60, 100, 140 and 160 kPa), with three replications in two consecutive crops of sunflower, totaling 60 experimental plots. For statistical quality control we used the five salinity levels of water and set the pressure in 160 kPa of 15 trials irrigation the emitters new for , with 210 and 350 hours of operation. Flow variation of self-compensating emitters were considered low analyzed over time being within the recommendation of ± 7% of the nominal flow. emitter obtained exponent values between 0.02 to 0.09, classified as self-compensating being in accordance with the manufacturer's data. The flow that is closer to that recommended by the manufacturer on new issuers occurred in pressure of 60 kPa and salinity of 0.6 dS m-1, when it increased uptime for 210 and 350 hours, the behavior was similar to new issuers. The values of the coefficients found CUC, CUD, CUE, FVC, GE and EA, were considered excellent and were not significantly influenced by the levels of salts in the irrigation water and the interaction between salinity and pressure when new, and are influenced by pressure service applied. The interaction between (S x P) influenced significantly the coefficients analyzed for evaluations carried out with 210 and 350 hours of operation, except for the CVq with 350 hours of operation. The performance was considered satisfactory emitters using saline water, the pressure of 60 kPa which resulted in better cost benefit. The Shewhart charts is a tool capable of diagnosing changes in the irrigation system showing the time to do maintenance. The emitters were considered capable when new, after 210 and 350 hours operation need of maintenance so you can keep within the limits of control making the emitter able. The process capability index is a tool to diagnose whether the irrigation system is able to keep under control, ie, whether it will be able to maintain acceptable levels of uniformity, helping the irrigator decision making.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/4229-
dc.date.accessioned2019-06-10T20:27:31Z-
dc.date.available2019-06-10-
dc.date.available2019-06-10T20:27:31Z-
dc.typeDissertaçãopt_BR
dc.subjectGotejamentopt_BR
dc.subjectSalinidadept_BR
dc.subjectUniformidade de Irrigaçãopt_BR
dc.subjectSistemas de Irrigaçãopt_BR
dc.subjectEscassez de Águapt_BR
dc.subjectDrip Emitterspt_BR
dc.subjectSalinitypt_BR
dc.subjectIrrigation Uniformitypt_BR
dc.subjectIrrigation Systemspt_BR
dc.subjectWater Shortagept_BR
dc.rightsAcesso Abertopt_BR
dc.creatorSILVA, Patrícia Ferreira da.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeUniformity of flow hose dripper self-compensating using saline water.pt_BR
dc.description.sponsorshipCapespt_BR
dc.identifier.citationSILVA, Patrícia Ferreira da. Uniformidade de vazão em mangueira gotejadora autocompensante utilizando água salina. 2014. 97 f. Dissertação (Mestrado em Engenharia Agrícola) – Programa de Pós-Graduação em Engenharia Agrícola, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande, Paraíba, Brasil, 2014. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/4229pt_BR
Appears in Collections:Mestrado em Engenharia Agrícola.

Files in This Item:
File Description SizeFormat 
PATRÍCIA FERREIRA DA SILVA – DISSERTAÇÃO (PPGEA) 2014.pdfPatrícia Ferreira da Silva - DISSERTAÇÃO PPGEA 20141.86 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.