Please use this identifier to cite or link to this item:
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/33203
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator.ID | NOVAIS, D. J. F. V. | pt_BR |
dc.creator.Lattes | http://lattes.cnpq.br/1175228862291347 | pt_BR |
dc.contributor.advisor1 | ARAÚJO, Carlos José de. | - |
dc.contributor.advisor1ID | DE ARAÚJO, C. J. | pt_BR |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/9466801408291152 | pt_BR |
dc.contributor.advisor-co1 | GRASSI, Estephanie Nobre Dantas. | - |
dc.contributor.advisor-co1ID | GRASSI, E. N. D. | pt_BR |
dc.contributor.advisor-co1Lattes | http://lattes.cnpq.br/6767760159280554 | pt_BR |
dc.contributor.referee1 | AMORIM JÚNIOR, Wanderley Ferreira de. | - |
dc.contributor.referee2 | ARAÚJO , Anna Carla Monteiro de. | - |
dc.description.resumo | Ligas com Memória de Forma são materiais inteligentes que possuem a capacidade de recuperar grandes deformações quando comparados a materiais metálicos comuns, como o aço e o titânio. Entre estas ligas, as mais conhecidas são as do sistema Ni-Ti, como o NiTiNOL e as ligas Ti-Ni-Nb, que possuem baixo módulo de elasticidade e elevada resistência mecânica e a corrosão e por isso vêm sendo utilizadas em diversas áreas, incluindo a medicina. Contudo, o níquel presente nestas ligas é considerado tóxico e, em casos especíĄcos, como desgaste da camada de óxido de titânio na superfície do material, pode expor o paciente à toxicidade do níquel. Desta forma, surge como opção para uso na área medicinal a liga Ti-Nb, que é composta somente de elementos biocompatíveis e possui outras propriedades desejáveis para tal uso, como elevada conformabilidade mecânica, resistência à corrosão e baixo módulo de elasticidade. Desta forma, este trabalho visa fabricar e caracterizar um liga Ti-25Nb (%at.), além de fabricar e testar protótipos de dispositivos médicos implantáveis: placas de Ąxação óssea (PFO) e grampos ortopédicos. A liga foi fabricada por fusão a arco em ambiente inerte e laminada a frio até uma redução de 90% na espessura do lingote, resultando em uma lâmina de Ti-Nb. O contorno externo da PFO, assim como o corte do grampo ortopédico, foi realizado por meio de corte por eletroerosão a Ąo, enquanto os furos internos foram feitos por furação com brocas de aço rápido. A liga Ti-Nb fabricada apresentou recuperação máxima de 1,5% de deformação, tensão máxima de 670 MPa e deformação máxima de 12,55% até a ruptura a 37 °C, temperatura corpórea humana média, além de apresentar módulo de elasticidade de 57,32 GPa em ensaio de tração e 52,7 GPa em ensaio de ultramicrodureza Vickers. Também se mostrou não citotóxica pelo método de difusão em ágar e apresentou predominância da fase β em ensaio de Difração de Raio-X (DRX) devido à presença de 0,814% (%at.) de oxigênio, atuando como supressor da formação da martensita ortorrômbica durante o resfriamento. A PFO de Ti-Nb apresentou rigidez Ćexural de 35,44 N/mm e rigidez estrutural em Ćexão de 3,06×10-3 N/m2 , 1,54 vezes inferiores aos os valores obtidos para a PFO de aço, enquanto grampo ortopédico de Ti-Nb fabricado apresentou rigidez de 20,65 N/mm, 3,25 vezes menor que a do grampo fabricado em aço inoxidável. Diante disto, conclui-se que a liga Ti-Nb, por apresentar baixo módulo de elasticidade, superelasticidade e não ser citotóxico, é adequada para ser usada como material de dispositivos médicos implantáveis, conclusão corroborada pela comparação entre os dispositivos de Ti-Nb e os dispositivos de aço fabricados. | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | Centro de Ciências e Tecnologia - CCT | pt_BR |
dc.publisher.program | PÓS-GRADUAÇÃO EM ENGENHARIA MECÂNICA | pt_BR |
dc.publisher.initials | UFCG | pt_BR |
dc.subject.cnpq | Engenharia mecânica. | pt_BR |
dc.title | Liga superelástica ti-25nb (%at): processamento, caracterização e protótipos de dispositivos implantáveis. | pt_BR |
dc.date.issued | 2023-07-25 | - |
dc.description.abstract | Shape Memory Alloys are smart materials that have the ability to recover large deformations when compared to common metallic materials such as steel and titanium. Among these alloys, the most common belong to the Ni-Ti system, such as NiTiNOL and Ti-Ni-Nb alloys, which have a low Young modulus and high mechanical strength and corrosion resistance, and therefore have been used in several areas, including medicine. However, the nickel content in these alloys is considered toxic and, in speciĄc cases, such as wear of the titanium oxide layer on the surface of the material, can expose the patient to nickel toxicity. Thus, an option for use in the medical area is the Ti-Nb alloy, which is composed only of biocompatible elements and has other desirable properties, such as high mechanical conformability, corrosion resistance and low Young modulus. In this regard, this work aims to fabricate and characterize a Ti-25Nb (%at.) alloy, as well as to fabricate and test prototypes of implantable medical devices: bone plates and orthopedic staples. The alloy was fabricated by arc melting in an inert environment and cold rolled to a 90% reduction in ingot thickness, resulting in a Ti-Nb sheet. The outer contour of the bone plate, as well as the cutting of the bone staple, was performed by wire EDM cutting, while the inner holes were drilled using high-speed steel drills. The fabricated Ti-Nb alloy showed a maximum recovery of 1.5% strain, maximum stress of 670 MPa and maximum strain of 12.55% until rupture at 37 °C, the average human body temperature, in addition to presenting a Young modulus of 57.32 GPa in tensile test and 52.7 GPa in Vickers ultramicrohardness test. It also proved to be non-cytotoxic by agar diffusion method and showed predominance of β phase in X-ray diffraction (XRD) test due to the presence of 0.814% (%at.) oxygen, acting as a suppressor of orthorhombic martensite formation during cooling. The Ti-Nb bone plate presented bending stiffness of 35.44 N/mm and bending structural stiffness of 3.06×10-3 N/m2 , 1.54 times lower than the values obtained for the steel bone plate, while the Ti-Nb bone staple fabricated presented stiffness of 20.65 N/mm, 3.25 times lower than that of the staple fabricated in stainless steel. In face of this, it is concluded that the Ti-Nb alloy, by presenting low Young modulus, superelasticity and not being cytotoxic, is suitable to be used as a material of implantable medical devices, a conclusion corroborated by the comparison between the Ti-Nb devices and the fabricated steel devices. | pt_BR |
dc.identifier.uri | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/33203 | - |
dc.date.accessioned | 2023-11-27T19:42:58Z | - |
dc.date.available | 2023-11-27 | - |
dc.date.available | 2023-11-27T19:42:58Z | - |
dc.type | Dissertação | pt_BR |
dc.subject | Engenharia mecânica | pt_BR |
dc.subject | Processos de fabricação | pt_BR |
dc.subject | Liga com memória de forma | pt_BR |
dc.subject | Superelasticidade | pt_BR |
dc.subject | Ti-Nb | pt_BR |
dc.subject | Placa de fixação óssea | pt_BR |
dc.subject | Grampo ortopédico | pt_BR |
dc.subject | Mechanical engineering | pt_BR |
dc.subject | Manufacturing processes | pt_BR |
dc.subject | Shape memory alloy | pt_BR |
dc.subject | Superelasticity | pt_BR |
dc.subject | Bone fixation plate | pt_BR |
dc.subject | Orthopedic staple | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.creator | NOVAIS, Diego Jean Freitas Vieira. | - |
dc.publisher | Universidade Federal de Campina Grande | pt_BR |
dc.language | por | pt_BR |
dc.title.alternative | Superelastic alloy ti-25nb (%at): processing, characterization and prototypes of implantable devices. | pt_BR |
dc.description.sponsorship | CNPq | pt_BR |
dc.relation | CAPES | pt_BR |
dc.relation | SEBRAE | pt_BR |
dc.identifier.citation | NOVAIS, Diego Jean Freitas Vieira. Liga superelástica ti-25nb (%at): processamento, caracterização e protótipos de dispositivos implantáveis. 2023. 110 f. Dissertação (Mestrado em Engenharia Mecânica) – Programa de Pós-Graduação em Engenharia Mecânica, Centro de Ciências e Tecnologias, Universidade Federal de Campina Grande, Paraíba, Brasil, 2023. | pt_BR |
Appears in Collections: | Mestrado em Engenharia Mecânica. |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
DIEGO JEAN FREITAS VIEIRA NOVAIS - DISSERTAÇÃO (PPGEM) 2023.pdf | 22.49 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.