Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/23517
Full metadata record
DC FieldValueLanguage
dc.creator.IDSOUZA, J. C. N.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/3427392621768495pt_BR
dc.contributor.advisor1MONTEIRO, Veruschka Escarião Dessoles.-
dc.contributor.advisor1IDMONTEIRO, V. E. D.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/6102407715279049pt_BR
dc.contributor.advisor2SANTOS, Jeovana Jisla das Neves.-
dc.contributor.advisor2IDSANTOS, J. J. N.-
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/1855756430075567-
dc.contributor.referee1BARBOSA, Dayse luna.-
dc.contributor.referee1IDBARBOSA, D. L.pt_BR
dc.contributor.referee1Latteshttp://lattes.cnpq.br/7376198442355112pt_BR
dc.contributor.referee2GUERRA, Tuilly de Fátima Macedo Furtado.-
dc.contributor.referee2IDGUERRA, T. F. M. Fpt_BR
dc.contributor.referee2Latteshttp://lattes.cnpq.br/4898462224565553pt_BR
dc.description.resumoOs Resíduos Sólidos Urbanos (RSU) dispostos em aterros sanitários geram como subprodutos de sua degradação lixiviados e gases. Estes gases constituem uma significativa fonte de emissões antropogênicas de Gases de Efeito Estufa (GEE), causando prejuízos em escala local e global. As emissões nos aterros sanitários podem ocorrer naturalmente por meio dos drenos verticais, que quando bem dimensionados direcionam toda saída de gases do interior do maciço de RSU, podendo ser realizado seu aproveitamento energético ou queima. Porém uma parcela significativa denominada emissões fugitivas ocorrem de maneira não controlada através da camada de cobertura final, denominada liner, sendo seu correto dimensionamento e execução indispensáveis na mitigação dessas emissões. Nesse contexto, este trabalho objetiva analisar as emissões fugitivas de GEE na Célula 2 do Aterro Sanitário em Campina Grande- PB. Como metodologias foi feito uma avaliação do solo da camada e o monitoramento dos gases nos drenos verticais, na interface de transição solo-resíduo e a quantificação do fluxo ao longo da camada de cobertura com o emprego de placa de fluxo estática, culminando com a avaliação da eficiência de retenção dos gases pela camada. Os resultados apontaram que os gases produzidos são compatíveis ao estado metanotrofico de biodegradação dos resíduos, com uma média de 57,2% pra o CH4, 39% para CO2 e 1,3% para o O2, com fluxos observados pelo liner em 3,30 NL.h-1.m-2 para o CH4 e 3,83 NL.h-1.m-2 para CO2, apresentando-se em conformidade com normativas internacionais, apresentando boa eficiência de retenção aos gases pela camada de solo compactado, variando de 80 a 100%, sendo apoiada por condições geotécnicas, morfológicas e climáticas. O que permite concluir que para os pontos avaliados as emissões fugitivas apresentaram-se em conformidade com os limites estabelecidos em normativas internacionais, de modo que a camada de cobertura apresentou características geotécnicas adequadas ao uso como camada de cobertura de aterro sanitário, apresentado resultados que servem como parâmetros para estudos e projetos realizados em aterros sanitários com condições climáticas e geotécnicas semelhantes às observadas no Aterro Sanitário em Campina Grande-PB.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Tecnologia e Recursos Naturais - CTRNpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Civilpt_BR
dc.titleAnálise de emissões fugitivas de gases de efeito estufa em célula de aterro sanitário em Campina Grande - PB.pt_BR
dc.date.issued2018-12-
dc.description.abstractThe Municipal Solid Waste (MSW) disposed in landfills generate as by-products of their degradation leachate liquids and gases. These gases constitute a significant source of anthropogenic emissions of Greenhouse Gases causing losses on a local and global scale. Emissions from landfills can occur naturally through vertical drains, which, when properly dimensioned, direct all the exhaust gases inside the solid mass of the MSW, which can be used for energy recovery or burning. However, a significant portion denominated fugitive emissions occurs in an uncontrolled way through the final cover layer, called liner, and its correct sizing and execution are indispensable in the mitigation of these emissions. In this context, this work aims to analyze the fugitive emissions of Greenhouse Gases in Cell 2 of the Landfill in Campina Grande-PB. As methodologies, a soil evaluation of the layer and the monitoring of the gases in the vertical drains, at the soil-residue transition interface and the quantification of the flow along the cover layer were done using static flow chamber, culminating with the evaluation of the gas retention efficiency by the layer. The results indicated that the gases produced are compatible with the methanotrophic state of biodegradation of the residues, with an average of 57.2% for CH4, 39% for CO2 and 1.3% for O2, with flows observed through the liner in 3, 30 NL.h-1.m-2 for CH4 and 3.83 NL.h-1.m-2 for CO2, complying with international regulations, presenting good gas retention efficiency by compacted soil layer, varying from 80 to 100%, being supported by geotechnical, morphological and climatic conditions. This leads us to conclude that for the evaluated points the fugitive emissions were in compliance with the established limits, so that the cover layer presented geotechnical characteristics suitable for use as a landfill cover layer, presenting results that serve as parameters for studies and projects carried out in landfills with climatic and geotechnical conditions similar to those observed in the Landfill in Campina Grande-PB.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/23517-
dc.date.accessioned2022-02-14T14:31:29Z-
dc.date.available2022-02-14-
dc.date.available2022-02-14T14:31:29Z-
dc.typeTrabalho de Conclusão de Cursopt_BR
dc.subjectGases de efeito estufa - Campina Grande - PBpt_BR
dc.subjectEmissões fugitivas de gases de efeito estufapt_BR
dc.subjectAterro sanitário - gases - Campina Grande - PBpt_BR
dc.subjectCélula de aterro sanitário - Campina Grande - PBpt_BR
dc.subjectGeotecnia Ambientalpt_BR
dc.subjectSolo compactadopt_BR
dc.subjectBiogáspt_BR
dc.subjectEnsaio de placa de fluxopt_BR
dc.subjectGás metanopt_BR
dc.subjectCobertura de aterro sanitáriopt_BR
dc.subjectAvaliação do solo da camada - aterro sanitáriopt_BR
dc.subjectMonitoramento dos gases nos drenos - aterro sanitáriopt_BR
dc.subjectResíduos sólidos urbanospt_BR
dc.subjectGreenhouse gases - Campina Grande - PBpt_BR
dc.subjectFugitive greenhouse gas emissionspt_BR
dc.subjectLandfill - gases - Campina Grande - PBpt_BR
dc.subjectLandfill cell - Campina Grande - PBpt_BR
dc.subjectEnvironmental Geotechnicspt_BR
dc.subjectcompacted soilpt_BR
dc.subjectbiogaspt_BR
dc.subjectFlow plate testpt_BR
dc.subjectMethane gaspt_BR
dc.subjectLandfill coveragept_BR
dc.subjectSoil assessment of the layer - sanitary landfillpt_BR
dc.subjectMonitoring of gases in drains - sanitary landfillpt_BR
dc.subjectUrban solid wastept_BR
dc.rightsAcesso Abertopt_BR
dc.creatorSOUZA, Jordan Carneiro Martins de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeAnalysis of fugitive emissions of greenhouse gases in a sanitary landfill cell in Campina Grande - PBpt_BR
dc.identifier.citationSOUZA, Jordan Carneiro Martins de. Análise de emissões fugitivas de gases de efeito estufa em célula de aterro sanitário em Campina Grande - PB. 2018. 47f. Trabalho de Conclusão de Curso (Monografia), Curso de Bacharelado em Engenharia Civil, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande - Campina Grande - Paraíba - Brasil, 2018. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/23517pt_BR
Appears in Collections:Curso de Bacharelado em Engenharia Civil - CTRN - Relatórios de Estágio

Files in This Item:
File Description SizeFormat 
JORDAN CARNEIRO MARTINS DE SOUZA - TCC ENG. CIVIL CTRN 2018.pdf Jordan Carneiro Martins de Souza - TCC ENG. CIVIL CTRN 20181.35 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.