Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41994
Title: Volume de proteção e controle de cheias em reservatórios.
Other Titles: Protection volume and control of floods in reservoir.
???metadata.dc.creator???: QUEIROZ, Manoel Moisés F. de.
ALMEIDA, Rodrigo A.
PRETI, Agnaldo P.
Keywords: Cheias em reservatórios - controle;Reservatórios - cheias;Proteção e controle de cheias - reservatórios;Curva volume x duração - reservatórios;Floods in reservoirs - control;Reservoirs - floods;Flood protection and control - reservoirs;Volume x duration curve - reservoirs
Issue Date: 2006
Publisher: Universidade Federal de Campina Grande
Citation: QUEIROZ, Manoel Moisés F. de; ALMEIDA, Rodrigo A; PRETI, Agnaldo P. Volume de proteção e controle de cheias em reservatórios. In: XXXV CONGRESSO BRASILEIRO DE ENGENHARIA AGRÍCOLA. 35., 2006, João Pessoa - PB. Anais [...]. João Pessoa - PB: Universidade Federal da Paraíba, 2006. Simpósio Temático: Saneamento e Controle Ambiental (Recursos Naturais e Meio Ambiente). Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41994
???metadata.dc.description.resumo???: Existe conflito na utilização de reservatórios para controle de cheias e usos múltiplo da água, principalmente para a geração de energia elétrica. Para controlar cheias e necessário um volume vazio capaz de absorver uma eventual cheia sem causar danos nas áreas a jusante. Por outro lado, para gerar energia é desejável alocar o menor volume de proteção possível, ao passo que para controlar cheias e desejável ter uma estimativa confiável da possibilidade do reservatório falhar quando um dado volume de proteção é alocado. O objetivo deste trabalho foi construir a Curva Volume X Duração, empregada para estimar volume de espera, através do ajuste das séries de volumes máximos afluentes usando a distribuição GEV e momentos LH. Foram usados volumes afluentes observados em várias estações fluviométricas de rios do estado do Paraná. Todos os ajustes dos volumes máximos afluentes foram aceitos através do teste de qualidade de ajuste proposto por Wang (1998) com 5 % de significância. A curva Volume X Duração foi adequadamente construída usando valores de volumes máximos afluentes observados em diferentes estações fluviometricas do Paraná.
Abstract: There is a clear conflict between the reservoir utilization for control and use multiple of the water mainly for electric power generation. In order to control the floods, it is necessary to predict the availability of empty reservoir volumes, capable of absorbing some inflow parcels, to avoid or reduce the damage caused to the downstream area. From an energy standpoint, it is desirable to allocate the smallest possible protection volume, while from a flood control standpoint, it is desirable to have a reliable estimate of the possibility of the reservoir failing to control a flood when a given protection volume is allocated. The objective of this work was to obtain the Curve Volume X Duration using maXimum inflow with different duration fitted by GEV distribution and LH moments used to estimate the protection volume in reservoir. They were used maXimum affluent volumes of the Paraná Rivers recorded in various gauges. All the fit of the maXimum affluent volumes was agree by the appr0Ximate goodness-of-fit test of fitted generalized eXtreme value distribution using LH moments by WANG (1998) with 5% significance level. The Curve Volume X Duration was build appropriately using affluent volumes observed on gauges of the Paraná State.
Keywords: Cheias em reservatórios - controle
Reservatórios - cheias
Proteção e controle de cheias - reservatórios
Curva volume x duração - reservatórios
Floods in reservoirs - control
Reservoirs - floods
Flood protection and control - reservoirs
Volume x duration curve - reservoirs
???metadata.dc.subject.cnpq???: Engenharia Agrícola.
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41994
Appears in Collections:35º CONBEA 2006 - Simpósio Temático - Saneamento e Controle Ambiental (Recursos Naturais e Meio Ambiente)

Files in This Item:
File Description SizeFormat 
VOLUME DE PROTEÇÃO E CONTROLE DE CHEIAS EM RESERVATÓRIOS - XXXV CONBEA UFCG 2006.pdfVolume de proteção e controle de cheias em reservatórios. - XXXV CONBEA UFCG 2006222.05 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.