Please use this identifier to cite or link to this item:
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41840
Title: | Distribuição volumétrica de pontas 11002 com e sem indução de ar. |
Other Titles: | Distribution patterns of 11002 flat fan nozzles with and without airinduction under diferents condictions. |
???metadata.dc.creator???: | BAUER, F. C. RAETANO, C. G. PEREIRA, F. A. R. |
Keywords: | Pulverizador de barra;Máquinas agrícolas;Mecanização agrícola;Distribuição volumétrica de pontas - pulverização;Coeficiente de variação;Boom sprayer;Agricultural machinery;Agricultural mechanization;Volumetric distribution of nozzles - spraying;Coefficient of variation |
Issue Date: | 2006 |
Publisher: | Universidade Federal de Campina Grande |
Citation: | BAUER, F. C; RAETANO, C. G; PEREIRA, F. A. R. Distribuição volumétrica de pontas 11002 com e sem indução de ar. In: XXXV CONGRESSO BRASILEIRO DE ENGENHARIA AGRÍCOLA. 35., 2006, João Pessoa - PB. Anais [...]. João Pessoa - PB: Universidade Federal da Paraíba, 2006. Simpósio Temático: Máquinas e Mecanização Agrícola. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41840 |
???metadata.dc.description.resumo???: | Foi objetivo do trabalho avaliar a distribuição volumétrica de pontas de pulverização jato plano comum 11002 com e sem indução de ar, bem como o padrão de deposição da pulverização, através da estimativa do Coeficiente de Variação obtido pela simulação da sobreposição. As pontas foram posicionadas, isoladamente no centro da mesa de teste, a 30, 40 e 50 cm de altura e a 300 e 500 kPa de pressão. Foram avaliadas 20 unidades de cada tipo de ponta e a deposição média foi utilizada para simulação da deposição ao longo da barra pulverizadora, com as pontas espaçadas em 30, 40, 50 e 60 cm entre si. A uniformidade da distribuição foi estimada pelo cálculo do CV resultante da simulação da sobreposição das pontas em barra de 8 metros, sendo utilizados somente os 4 metros centrais no cálculo do CV. Os resultados mostraram haver diferenças relacionadas à deposição entre os dois tipos de pontas, com a ponta com indução de ar resultando em área de deposição inferior a ponta sem indução. Esse comportamento foi observado em todas as alturas de barra e nas duas pressões, podendo-se inferir que esse comportamento possa ser característico das pontas com indução de ar. |
Abstract: | This study evaluated the characteristics of spray distribution and uniformity by flat fan nozzles with and without air induction. Twenty units of flat fan 11002 nozzles with and without air induction were tested in patternator table. Each one of the units was tested separately, at the 0.30, 0.40 and 0.50 m above the patternator table and submitted to pressures of 300 and 500 kPa. The means of the colleted spray volume distribution of each nozzle types was evaluated and entered in a PC program. Based on the deposition patterns, distribution uniformity for nozzles spaced at 0.30, 0.40, 0.50 and 0.60 m was simulated in PC Program. The distribution uniformity was estimated by the Coefficient of Variation of the deposition simulated for 8 m boom. The PC Program simulated the distribution pattern of 8 m boom and calculated the Coefficient of Variation (CV) corresponding to each configuration. The results pointed out differents deposition for each nozzle type and the nozzle with air induction resulting in lower deposition area. That behavior was observed in all the bar heights and in the two pressures, could be inferred that behavior can be characteristic of the tips with air induction. |
Keywords: | Pulverizador de barra Máquinas agrícolas Mecanização agrícola Distribuição volumétrica de pontas - pulverização Coeficiente de variação Boom sprayer Agricultural machinery Agricultural mechanization Volumetric distribution of nozzles - spraying Coefficient of variation |
???metadata.dc.subject.cnpq???: | Engenharia Agrícola. |
URI: | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41840 |
Appears in Collections: | 35º CONBEA 2006 - Simpósio Temático - Máquinas e Mecanização Agrícola |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
DISTRIBUIÇÃO VOLUMÉTRICA DE PONTAS 11002 - XXXV CONBEA UFCG 2006.pdf | Distribuição volumétrica de pontas 11002 com e sem indução de ar. - XXXV CONBEA UFCG 2006 | 48.64 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.