Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41347
Title: Coeficientes de descarga de orifícios retangulares em parede delgada vertical curva.
Other Titles: Discharge coefficients for rectangular orifices in a curve thin plate.
???metadata.dc.creator???: AMARAL, Luís G. H. do.
RAMOS, Márcio M.
DENÍCULI, Wilson.
CECON, Paulo R.
Keywords: Escoamento simultâneo;Face interna convexa;Coeficientes de descarga;Parede delgada vertical curva;Hidráulica;Laboratório de Hidráulica - UFV;Simultaneous flow;Convex internal face;Discharge coefficients;Curved vertical thin wall;Hydraulics;Hydraulics Laboratory - UFV
Issue Date: 2006
Publisher: Universidade Federal de Campina Grande
Citation: AMARAL, Luís G. H. do; RAMOS, Márcio M; DENÍCULI, Wilson; CECON, Paulo R. Coeficientes de descarga de orifícios retangulares em parede delgada vertical curva. In: XXXV CONGRESSO BRASILEIRO DE ENGENHARIA AGRÍCOLA. 35., 2006, João Pessoa - PB. Anais [...]. João Pessoa - PB: Universidade Federal da Paraíba, 2006. Simpósio Temático: Engenharia de água e solo. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41347
???metadata.dc.description.resumo???: O objetivo desse trabalho foi analisar as influências da curvatura da parede e da operação simultânea de orifícios posicionados lado a lado sobre o coeficiente de descarga de orifícios retangulares em parede delgada vertical. A influência da curvatura da parede foi avaliada em orifícios retangulares de 40 x 80 mm perfurados em quatro tubos de PVC, um de seção quadrada e três de seção circular com diâmetros externos de 250, 350 e 450 mm. A influência da operação simultânea foi avaliada em um tubo de PVC de diâmetro externo de 250 mm, ao redor do qual foram perfurados oito orifícios retangulares de 40 x 80 mm. Verificou-se influência significativa da curvatura da parede sobre o coeficiente de descarga, sendo que esse diminuiu aproximadamente 3,5% para um aumento de 0,32 rad (18,3°) no ângulo a entre o eixo do orifício e a sua parede. Por outro lado, o aumento do número de orifícios operando simultaneamente provocou redução no coeficiente de descarga, devido à sobreposição dos jatos dentro do tubo e do afogamento dos orifícios nas maiores vazões.
Abstract: The objective of this work was to verify the influences of plate curvature and simultaneous operation of side by side orifices on discharge coefficient of rectangular orifices in vertical thin plate. The influence of plate curvature was evaluated in 40 x 80 mm rectangular orifices perforated in four PVC pipes, one with square section, and the other ones with cylindrical sections and external diameter of 250, 350 and 450 mm. The influence of simultaneous operation was evaluated in a 250 mm of external diameter pipe, with eight 40 x 80 mm rectangular orifices around it. Increasing 0.32 rad (18.3°) in angle a between orifice axis and its plate, the discharge coefficient decreased 3.5%. Otherwise, increasing number of orifices in simultaneous operation, the discharge coefficient decreased, because of jets superposition within the tube and submergence of the orifices in the highest flows.
Keywords: Escoamento simultâneo
Face interna convexa
Coeficientes de descarga
Parede delgada vertical curva
Hidráulica
Laboratório de Hidráulica - UFV
Simultaneous flow
Convex internal face
Discharge coefficients
Curved vertical thin wall
Hydraulics
Hydraulics Laboratory - UFV
???metadata.dc.subject.cnpq???: Engenharia Agrícola.
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41347
Appears in Collections:35º CONBEA 2006 - Simpósio Temático - Engenharia de Água e Solo

Files in This Item:
File Description SizeFormat 
COEFICIENTES DE DESCARGA - XXXV CONBEA UFCG 2006.pdfCoeficientes de descarga de orifícios retangulares em parede delgada vertical curva. - XXXV CONBEA UFCG 2006195.04 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.