Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41335
Title: Calibração em laboratório de sensores fdr (frequency domain reflectometry) para medição da umidade do solo.
Other Titles: Laboratory calibration of fdr (frequency domain reflectometry) sensors for soil moisture determination.
???metadata.dc.creator???: SANTOS, Ricardo M.
OLIVEIRA, Aureo S. de.
BRANDÃO, Flávia Janaína C.
PEREIRA, Francisco Adriano de C.
Keywords: Sensores FDR;Umidade do solo - sensores;Sonda de capacitância;Reflectometria;Frequency Domain Reflectometry - FDR;FDR Sensors;Soil Moisture - Sensors;Capacitance Probe;Reflectometry;Frequency Domain Reflectometry - FDR
Issue Date: 2006
Publisher: Universidade Federal de Campina Grande
Citation: SANTOS, Ricardo M; OLIVEIRA, Aureo S. de; BRANDÃO, Flávia Janaína C; PEREIRA, Francisco Adriano de C. Calibração em laboratório de sensores fdr (frequency domain reflectometry) para medição da umidade do solo. In: XXXV CONGRESSO BRASILEIRO DE ENGENHARIA AGRÍCOLA. 35., 2006, João Pessoa - PB. Anais [...]. João Pessoa - PB: Universidade Federal da Paraíba, 2006. Simpósio Temático: Engenharia de água e solo. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41335
???metadata.dc.description.resumo???: A determinação da umidade do solo é um parâmetro importante em estudos de irrigação, drenagem, armazenamento de água e movimentação de água e solutos no perfil. Vários são hoje os equipamentos destinados a tal fim. A determinação da umidade é feita em geral através de uma propriedade do solo sensível à variação do conteúdo de água no solo, a exemplo da constante dielétrica. O objetivo deste estudo foi calibrar em laboratório a partir de monólitos um sensor FDR, modelo Sentry 200 AP. A calibração seguiu um modelo exponencial e mostrou alta correlação para seis profundidades do perfil de solo (10, 30, 50, 70 e 90 cm) dos Tabuleiros Costeiros da Bahia. Os coeficientes de determinação variaram de 0,937 (70 cm) a 0,996 (90 cm). O método de calibração portanto revelou-se adequado para uso prático da sonda em condições de campo.
Abstract: The determination of soil water content is an essential data for soil and water management, irrigation, drainage, and monitoring of water and solute movement into the soil profile. Actually, there is a number of equipment for determination of soil moisture content and they work according to different principles. But, they usually estimates the water content based on a given soil property that follows the variation of water content. Thus, the objective of this work was to calibrate an FDR sensor model Sentry 200 AP. The calibration followed an exponential model e it showed high correlation between sensor reading and gravimetric moisture, in all depths (10, 30, 50, 70, 90, 110 cm) of the profile of a soil from the Costal Tablelands of Bahia. The determination coefficient varied from 0.937 (70 cm) to 0,996 (90 cm). The calibration procedure here adopted revealed to be appropriate for this type of sensor when it has to be used under filed conditions.
Keywords: Sensores FDR
Umidade do solo - sensores
Sonda de capacitância
Reflectometria
Frequency Domain Reflectometry - FDR
FDR Sensors
Soil Moisture - Sensors
Capacitance Probe
Reflectometry
Frequency Domain Reflectometry - FDR
???metadata.dc.subject.cnpq???: Engenharia Agrícola.
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41335
Appears in Collections:35º CONBEA 2006 - Simpósio Temático - Engenharia de Água e Solo

Files in This Item:
File Description SizeFormat 
CALIBRAÇÃO EM LABORATÓRIO DE SENSORES FDR - XXXV CONBEA UFCG 2006.pdfCalibração em laboratório de sensores fdr (frequency domain reflectometry) para medição da umidade do solo. - XXXV CONBEA UFCG 2006505.58 kBAdobe PDFView/Open