Please use this identifier to cite or link to this item:
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41319
Title: | Calibração da sonda de capacitância Diviner 2000® em um argissolo. |
Other Titles: | Calibration of Diviner 2000® capacitance probe in an argisol. |
???metadata.dc.creator???: | SILVA, Cláudio R. ANDRADE JÚNIOR, Aderson S. MELO, Francisco B. SOUSA, Antonio B. SOUZA, Claudinei F. |
Keywords: | Argissolo;Sonda de capacitância Diviner 2000®;Sonda de FDR;Umidade do solo;Sensor - umidade do solo;Argisol;Diviner 2000® capacitance probe;FDR probe;Soil moisture;Sensor - soil moisture |
Issue Date: | 2005 |
Publisher: | Universidade Federal de Campina Grande |
Citation: | SILVA, Cláudio R; ANDRADE JÚNIOR, Aderson S; MELO, Francisco B; SOUSA, Antonio B; SOUZA, Claudinei F. Calibração da sonda de capacitância Diviner 2000® em um argissolo. In: XXXV CONGRESSO BRASILEIRO DE ENGENHARIA AGRÍCOLA. 35., 2006, João Pessoa - PB. Anais [...]. João Pessoa - PB: Universidade Federal da Paraíba, 2006. Simpósio Temático: Engenharia de água e solo. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41319 |
???metadata.dc.description.resumo???: | Sensores de umidade do solo por capacitância são alternativas aos métodos tradicionais de quantificação do teor de água do solo, fornecendo leituras seguras, rápidas e em profundidade no perfil do solo. Uma sonda de capacitância Diviner 2000® foi calibrada para um Argissolo Vermelho Amarelo, no Campo Experimental da Embrapa Meio-Norte, situado no município de Teresina, PI. Seis tubos de acesso foram instalados em uma disposição de 5 m por 2 m. Três níveis de conteúdo de água no solo (seco, úmido e saturado) foram aplicados em duas repetições. Efetuaram-se leituras do equipamento, para cada 0,1 m de solo, até 1,0 m de profundidade, juntamente com a coleta de amostras de solo para a determinação da umidade volumétrica ( v). A curva de calibração proposta, ajustada por análise de regressão, foi significativamente relacionada com as medidas do equipamento, com alta correlação (R2 =0,93) e baixo erro-padrão (0,014 m3 m-3). Apesar de subestimar os valores de v (9,2% em média), a curva de calibração padrão do Diviner 2000® é aceitável para o solo em estudo. |
Abstract: | Capacitance sensors are alternatives to most common soil water content methods, providing readings safely and rapidly with depth. In this study, a capacitance probe (Diviner 2000®) was calibrated in a Red Yellow Argisoll at Experimental area of Embrapa Meio-Norte, Teresina, Piaui State, Brazil. Six access tubes were installed in a 5 by 2 m grid system. Three moisture levels (dry, moist and satured soil) were applied in two replications. Readings of device were made for every 0.1 m until 1.0 m depth as well as collecting of soil samples to determine the volumetric soil water ( v). The calibration equation, derived by regression analysis, was significantly related with measurements of equipment with high correlation (R2 =0.93) and lower standard error (0.014 m3 m-3). Despite underestimating values of v by 9.2%, the manufacture’s calibration presents in Diviner 2000® is acceptable for this soil. |
Keywords: | Argissolo Sonda de capacitância Diviner 2000® Sonda de FDR Umidade do solo Sensor - umidade do solo Argisol Diviner 2000® capacitance probe FDR probe Soil moisture Sensor - soil moisture |
???metadata.dc.subject.cnpq???: | Engenharia Agrícola. |
URI: | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41319 |
Appears in Collections: | 35º CONBEA 2006 - Simpósio Temático - Engenharia de Água e Solo |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
CALIBRAÇÃO DA SONDA DE CAPACITÂNCIA DIVINER 2000 - XXXV CONBEA UFCG 2006.pdf | Calibração da sonda de capacitância Diviner 2000® em um argissolo. - XXXV CONBEA UFCG 2006 | 76.72 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.