Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/40973
Title: Determinação da fração de água nebulizada ( β ) no interior de galpões climatizados para criação de frangos de corte.
Other Titles: Determination of fraction of the misting rate ( β ) inside of acclimatized broiler housings.
???metadata.dc.creator???: CARVALHO, Valcimar F. de.
YANAGI JUNIOR, Tadayuki.
DAMASCENO, Flávio A.
MORAIS, Sandra R. P.
TINÔCO, Ilda F. F.
Keywords: Galpões rurais;Construções rurais;Água nebulizada;Frangos de corte;Avicultura;Rural sheds;Rural buildings;Water mist;Broilers;Poultry farming
Issue Date: 2006
Publisher: Universidade Federal de Campina Grande
Citation: CARVALHO, Valcimar F. de; YANAGI JUNIOR, Tadayuki; DAMASCENO, Flávio A; MORAIS, Sandra R. P; TINÔCO, Ilda F. F. Determinação da fração de água nebulizada (b) no interior de galpões climatizados para criação de frangos de corte. In: XXXV CONGRESSO BRASILEIRO DE ENGENHARIA AGRÍCOLA. 35., 2006, João Pessoa - PB. Anais [...]. João Pessoa - PB: Universidade Federal da Paraíba, 2006. Simpósio Temático: Construções Rurais e Ambiência. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/40973
???metadata.dc.description.resumo???: O objetivo do presente trabalho é determinar a fração de água nebulizada (β) no interior de um galpão climatizado para criação de frangos de corte. A determinação de β foi feita por meio de um balanço de calor em regime permanente e de dados de temperatura de bulbo seco (tbs), umidade relativa (UR) e velocidade do ar (V), bem como da vazão de água nebulizada medidos em um galpão climatizado equipado com ventilação em modo túnel, com pressão negativa e sistema de resfriamento evaporativo do tipo material poroso umedecido e nebulização, funcionando simultaneamente. O galpão foi divido em quatro seções (30, 60, 90 e 120 m), onde a tbs, UR e V foram medidos, sendo analisados somente os dados nos trechos no qual o sistema de nebulização estava instalado. Os valores de β foram calculados por meio da equação de balanço de calor para períodos no qual não ocorreram mudanças de tbs e UR por pelo menos cinco minutos. A melhor equação ajustada, linear sem intercepto, possui r2 = 0,88, com coeficientes das variáveis tbs e UR significativos (P>0,0001 e P>0,0197, respectivamente). A equação de β foi incorporada ao modelo de transferência de calor e massa para predição da tbs e UR ao longo de um galpão climatizado, o que resultou nos erros padrões de 0,81ºC e 5,51%, respectivamente.
Abstract: The goal of the present work is to determine the fraction of the mist which evaporates (β) into an acclimatized broiler housing. Determination of β was made by a steady-state heat balance and the data of air dry bulb temperature (tdb), relative humidity (RH) and velocity (V); as well as the flow rate of mist water measured in an acclimatized broiler housing equipped with tunnel ventilation with negative pressure and pad and misting evaporative cooling systems, working simultaneously. The broiler housing was divided in 4 sections (30, 60, 90 e 120 m), where the data of tdb, RH and V were measured, being analyzed only the data in the sections in which the misting system was installed. The values of β were calculated by heat balance equation for the periods in which no changes in tdb were detected for at least 5 minutes. The best equation fitted, linear without intercept, has r2 = 0.88, with coefficients of the variables tdb and RH significant (P>0.0001 and P>0.0197, respectively). The β equation was incorporated in the model to predict tdb and RH throughout an acclimatized housing, which resulted in standard errors of 0.81ºC and 5.51%, respectively
Keywords: Galpões rurais
Construções rurais
Água nebulizada
Frangos de corte
Avicultura
Rural sheds
Rural buildings
Water mist
Broilers
Poultry farming
???metadata.dc.subject.cnpq???: Engenharia Agrícola.
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/40973
Appears in Collections:35º CONBEA 2006 - Simpósio Temático - Construções Rurais e Ambiência

Files in This Item:
File Description SizeFormat 
DETERMINAÇÃO DA FRAÇÃO DE ÁGUA NEBULIZADA - XXXV CONBEA UFCG 2006.pdfDeterminação da fração de água nebulizada ( β ) no interior de galpões climatizados para criação de frangos de corte. - XXXV CONBEA UFCG 2006.73.03 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.