Please use this identifier to cite or link to this item:
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39480
Title: | Modelos matemáticos para o microgotejador Katif. |
Other Titles: | Mathematical models for the Katif microdripper. |
???metadata.dc.creator???: | LUCENA, Kennedy Flávio Meira de. AZEVEDO, Carlos Alberto Vieira de. DANTAS NETO, José. MATOS, José de Arimatea de. MEDEIROS, Mônica Garcia Agra de. |
Keywords: | Microgotejador Katif;Modelagem matemática - microgotejamento;Irrigação;Gotejamento;Dimensionamento - microgotejador;Katif Microdripper;Mathematical modeling - microdripper;Irrigation;Drip;Sizing - microdripper |
Issue Date: | 1997 |
Publisher: | Universidade Federal de Campina Grande |
Citation: | LUCENA, Kennedy Flávio Meira de; AZEVEDO, Carlos Alberto Vieira de; DANTAS NETO, José; MATOS, José de Arimatea de; MEDEIROS, Mônica Garcia Agra de. Modelos matemáticos para o microgotejador Katif. In: CONGRESSO BRASILEIRO DE ENGENHARIA AGRÍCOLA. Sessão Pôster: Engenharia de Água e Solo. Campina Grande - PB, 26., 1997. Pôster [...]. Campina Grande - PB: Universidade Federal da Paraíba, 1997. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39480 |
???metadata.dc.description.resumo???: | Tentou-se encontrar um modelo matemático que melhor caracterizasse a relação entre vazão e pressão do microgotejador Katif (3,75 l/h). Foram testados 25 modelos matemáticos, através do software CURVEFIT. Os ensaios de laboratório foram com 18 emissores, submetidos a pressões variando de 30 a 360 kPa.. A equação potencial apresentou um coeficiente de correlação (0,232) muito baixo, enquanto que a função Módulo de Hoerl foi a que mostrou-se mais adequada. Analisando cinco modelos selecionadas, verificou-se que, no dimensionamento de linhas laterais, não houve diferenças na seleção de diâmetros comerciais. Entretanto, na estimativa de lâminas d'água aplicadas, o modelo potencial gerou erros de até 8%. |
Abstract: | It was tried to find a mathematical model that would better describe the relationship between discharge and pressure for the Katif emitters (3.75 l/h). It was tested 25 mathematical models, by using the software CURVEFIT. The laboratory tests were with 18 emitters, submitted to pressures varying from 30 to 360 kPa. The power equation presented a very low correlation coefficient (0.232), while the Hoerl module function was the one that showed to be most adequate. Analyzing five selected models, it was verified that, in the design of lateral lines, there were no differences in the selection of the commercial pipe diameters. However, in the estimation of applied water depth, the power model generates errors up to 8%. |
Keywords: | Microgotejador Katif Modelagem matemática - microgotejamento Irrigação Gotejamento Dimensionamento - microgotejador Katif Microdripper Mathematical modeling - microdripper Irrigation Drip Sizing - microdripper |
???metadata.dc.subject.cnpq???: | Engenharia Agrícola. |
URI: | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39480 |
Appears in Collections: | 26º CONBEA 1997 - Seção Pôster - Engenharia de Água e Solo |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
MODELOS MATEMÁTICOS PARA O MICROGOTEJADOR KATIF - EVENTO CONBEA UFCG 1997.pdf | Modelos matemáticos para o microgotejador Katif. - Evento Conbea UFCG 1997. | 260.12 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.