Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39332
Full metadata record
DC FieldValueLanguage
dc.creator.IDOLIVEIRA, E. F. A. B.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/2214043035252643pt_BR
dc.contributor.advisor1LIMA, Raoni Venâncio dos Santos.-
dc.contributor.advisor1IDLIMA, R. V. S.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1144772512685166pt_BR
dc.contributor.advisor-co1LEAL, Lilianne de Queiroz.-
dc.contributor.advisor-co1IDLEAL, L. Q.pt_BR
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/0998715780950433pt_BR
dc.contributor.referee1PANET, Miriam de Farias.-
dc.contributor.referee1IDPANET, M. F.pt_BR
dc.contributor.referee1Latteshttp://lattes.cnpq.br/5425360948252283pt_BR
dc.contributor.referee2TAVARES, Jean Carlo Fechine.-
dc.contributor.referee2IDTAVARES, J. C. F.pt_BR
dc.contributor.referee2Latteshttp://lattes.cnpq.br/0062912559752784pt_BR
dc.description.resumoCom os crescentes impactos das mudanças climáticas e acelerado consumo energético das edificações, houve um aumento nos estudos da eficiência energética. Nas edificações públicas brasileiras cresceu o consumo de energia por metro quadrado, sendo as universidades públicas responsáveis por 21% das despesas com energia elétrica. Para avaliar a eficiência energética, foi criado, em 2009, o Regulamento Técnico da Qualidade do Nível de Eficiência Energética de Edifícios Comerciais, de Serviços e Públicos (RTQ-C). Em 2018, o Inmetro publicou a Instrução Normativa Inmetro para o Nível de Eficiência Energética de Edificações Comerciais, de Serviços e Publicas (INI-C), com intuito de substituir o RTQ-C. O objetivo deste trabalho foi avaliar e classificar o desempenho energético da envoltória do bloco de aulas (CW), do curso de Arquitetura e Urbanismo, da Universidade Federal de Campina Grande, utilizando o método simplificado da INI-C. Para aplicar o método, foram levantados parâmetros para serem inseridos em metamodelos de análise. O resultado da aplicação do método para obtenção desempenho energético, revelou um percentual de redução no consumo de energia primária de 29%, que classificou a envoltória do bloco CW como nível A. Para compreender o resultado foram comparadas as condições reais da edificação com as condições de referência equivalentes ao nível D, sendo observada grande influência da cobertura e dos elementos de sombreamento do edifício na classificação obtida. Quanto ao método utilizado, para edificações condicionadas artificialmente é uma boa ferramenta de análise, enquanto para as edificações híbridas, é uma forma muito simplificada, que não analisa elementos importantes do edifício, como os cobogós. Assim, conclui-se que é importante avaliar o desempenho energético da edificação, buscando compreender o resultado para possíveis melhorias no próprio edifício e em edifícios com características semelhantes, para disseminar o estudo de eficiência energética em edificações.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Tecnologia e Recursos Naturais - CTRNpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqArquitetura e Urbanismopt_BR
dc.titleAvaliação da eficiência energética da envoltória através do método simplificado da INI-C: estudo de caso do bloco CW da UFCG.pt_BR
dc.date.issued2024-10-31-
dc.description.abstractWith the growing impacts of climate change and the accelerated energy consumption of buildings, there has been an increase in studies on energy efficiency. In brazilian public buildings, energy consumption per square meter has risen, with public universities accounting for 21% of electricity expenses. To assess energy efficiency, the Technical Regulation on the Quality of Energy Efficiency Levels for Commercial, Service, and Public Buildings (RTQ-C) was created in 2009. In 2018, Inmetro published the Inmetro Normative Instruction for the Energy Efficiency Level of Commercial, Service, and Public Buildings (INI-C), aiming to replace the RTQ-C. The objective of this work was to evaluate and classify the energy performance of the envelope of the lecture Bloco (CW) of the Architecture and Urbanism course at the Universidade Federal de Campina Grande, using the simplified method of INI-C. To apply the method, parameters were collected to be inserted into analysis metamodels. The result of applying the method to obtain energy performance revealed a 29% reduction in primary energy consumption, classifying the Bloco CW envelope as level A. To understand the result, the actual conditions of the building were compared with reference conditions equivalent to level D, showing a significant influence of the building's roof and shading elements on the classification obtained. As for the method used, it is a good analysis tool for artificially conditioned buildings, while for hybrid buildings, it is a very simplified method that does not analyze important elements of the building, such as cobogós. Thus, it is concluded that it is important to evaluate the energy performance of the building, seeking to understand the result for possible improvements in the building itself and in buildings with similar characteristics, to disseminate the study of energy efficiency in buildings.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39332-
dc.date.accessioned2024-12-05T19:00:35Z-
dc.date.available2024-12-05-
dc.date.available2024-12-05T19:00:35Z-
dc.typeTrabalho de Conclusão de Cursopt_BR
dc.subjectEficiência Energética da Envoltóriapt_BR
dc.subjectBloco de Aulas (CW) – Universidade Federal de Campina Grandept_BR
dc.subjectNível de Eficiência Energética de Edificações Comerciais, de Serviços e Públicas (INI-C)pt_BR
dc.subjectConforto Ambientalpt_BR
dc.subjectEnergy Efficiency of the Building Envelopept_BR
dc.subjectClassroom Block (CW) – Federal University of Campina Grandept_BR
dc.subjectEnergy Efficiency Level of Commercial, Service and Public Buildings (INI-C)pt_BR
dc.subjectEnvironmental Comfortpt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorOLIVEIRA, Emmanuella Flora Amaral Barbosa de.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeEvaluation of the energy efficiency of the envelope through the simplified INI-C method: case study of the CW block of UFCG.pt_BR
dc.identifier.citationOLIVEIRA, Emmanuella Flora Amaral Barbosa de. Avaliação da eficiência energética da envoltória através do método simplificado da INI-C: estudo de caso do bloco CW da UFCG. 2024. 90 f. Monografia (Bacharelado em Arquitetura e Urbanismo) - Universidade Federal de Campina Grande, Centro de Tecnologia e Recursos Naturais, Campina Grande, Paraíba, Brasil, 2024. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39332pt_BR
Appears in Collections:Curso de Bacharelado em Arquitetura e Urbanismo - CTRN - Monografias



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.