Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39326
Title: Desempenho do tubo “PORITEX” em solo arenoso.
Other Titles: Performance of “PORITEX” pipe in sandy soil.
???metadata.dc.creator???: CALHEIROS, Rinaldo de O.
SAKAI, Emilio.
ARRUDA, Flávio B.
FUJIWARA, Mamor.
CRUCIANI, Décio E.
Keywords: Irrigação localizada;Tubo exudante;Tubo PORITEX;Solo arenoso;Localized irrigation;Exudant tube;PORTITEX tube;Sandy soil
Issue Date: 1997
Publisher: Universidade Federal de Campina Grande
Citation: CALHEIROS, Rinaldo de O; SAKAI, Emilio; ARRUDA, Flávio B; FUJIWARA, Mamor; CRUCIANI, Décio E. Desempenho do tubo “PORITEX” em solo arenoso. In: CONGRESSO BRASILEIRO DE ENGENHARIA AGRÍCOLA. Sessão Pôster: Engenharia de Água e Solo. Campina Grande - PB, 26., 1997. Pôster [...]. Campina Grande - PB: Universidade Federal da Paraíba, 1997. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39326
???metadata.dc.description.resumo???: O desempenho hidráulico e na distribuição de água no solo de um tubo exudante de marca comercial “PORITEX” foi testado em solo arenoso-Podzólico de Lins e Marília, variação Marília, unidade Serrinha-visando subsidiar recomendação quanto a seu espaçamento operacional e pressão/vazão de serviço. Utilizaram-se três diferentes pressões de serviço -0.024; 0.045 e 0.062 MPa que resultaram nas vazões de 0.057 + 2.25 . 10-3; 0.038 + 4.47 . 10-3 e 0.076 + 5.42 . 10-3 l. min -1. m-1 , respectivamente. Num caso hipotético de uma cultura de feijão, sob evapotranspiração de 4.0mm/dia, aliando-se o tempo de irrigação com o fator “P” de porcentagem de molhamento do solo, recomenda-se as pressões de serviço de 0.045 e 0.062 MPa .
Abstract: The hydraulic performance and water distribution of an exuding tube, commercially called “PORITEX” was tested on a sandy soil-Podzolic of Lins and Marília, variation Marília, unit Serrinha. Our aim was provide information on the spacing conditions, water pressure and flow, in order to set recommendations for use in irrigation. The water pressure was set to 0.024, 0.045 and 0.062 MPa, resulting in water flow of 0.057 + 2.25 . 10-3; 0.038 + 4.47 . 10-3 e 0.076 + 5.42 . 10-3 l. min.-1. m-1 , respectively. With base on a hypotetic design of irrigated bean, under a evapotranspiration of 4.0mm.day-1, relationing the irrigation time with P factor of percentage of wetting of soil, it is recommended the pressures of 0.045 or 0.062 MPa.
Keywords: Irrigação localizada
Tubo exudante
Tubo PORITEX
Solo arenoso
Localized irrigation
Exudant tube
PORTITEX tube
Sandy soil
???metadata.dc.subject.cnpq???: Engenharia Agrícola.
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39326
Appears in Collections:26º CONBEA 1997 - Seção Pôster - Engenharia de Água e Solo

Files in This Item:
File Description SizeFormat 
DESEMPENHO DO TUBO “PORITEX” EM SOLO ARENOSO - EVENTO CONBEA UFCG 1997.pdfDesempenho do tubo “PORITEX” em solo arenoso. - Evento Conbea UFCG 1997.326.34 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.