Please use this identifier to cite or link to this item:
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39260
Title: | Avaliação do desempenho de sistemas de drenagem subterrânea do perímetro irrigado de bebedouro - Petrolina-PE. |
Other Titles: | Evaluation of the performance of underground drainage systems in the irrigated perimeter of Bebedouro - Petrolina-PE. |
???metadata.dc.creator???: | AMORIM, Valdiney Bezerra de. AZEVEDO, Carlos Alberto Vieira de. BATISTA, Manoel de Jesus. CALDAS JÚNIOR, Walter. DANTAS NETO, José. |
Keywords: | Sistemas de drenagem subterrânea;Perímetro Irrigado de Bebedouro - Petrolina - PE;Drenagem subterrânea;Carga hidráulica;Underground drainage systems;Irrigated perimeter of Bebedouro - Petrolina - PE;Underground drainage;Hydraulic load |
Issue Date: | 1997 |
Publisher: | Universidade Federal de Campina Grande |
Citation: | AMORIM, Valdiney Bezerra de; AZEVEDO, Carlos Alberto Vieira de; BATISTA, Manoel de Jesus; CALDAS JÚNIOR, Walter; DANTAS NETO, José. Avaliação do desempenho de sistemas de drenagem subterrânea do perímetro irrigado de bebedouro - Petrolina-PE. In: CONGRESSO BRASILEIRO DE ENGENHARIA AGRÍCOLA. Sessão Pôster: Engenharia de Água e Solo. Campina Grande - PB, 26., 1997. Pôster [...]. Campina Grande - PB: Universidade Federal da Paraíba, 1997. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39260 |
???metadata.dc.description.resumo???: | O desempenho de sistemas de drenagem subterrânea do Perímetro Irrigado de Bebedouro, Petrolina-PB, foram avaliados a partir do tempo de rebaixamento da carga hidráulica. Dentre os cinco lotes do projeto avaliados, identificou-se uma área que não necessita do emprego da drenagem subterrânea, nas profundidades de até 2,0m. Em uma área, o sistema de drenagem não está conseguindo promover um rebaixamento satisfatório do lençol freático em três dias, no entanto, em outra o sistema está drenando além das expectativas de projeto. Os demais sistemas exibiram um desempenho satisfatório, atendendo, inclusive, aos requisitos projetados. |
Abstract: | The Bebedouro irrigation district subsurface drainage systems performance were evaluated, basing on the time of hydraulic head dropping. Among the five drainage systems evaluated, it was identified a area that does not need subsurface drainage, at the depths up to 2.0m. There is a area in which the drainage system is not being able to perform a satisfactory dropping in the water table, during a three days period, but in another one the system is draining over the project expectancy. The others systems exhibited a good performance, even satisfying the drainage system design requirements. |
Keywords: | Sistemas de drenagem subterrânea Perímetro Irrigado de Bebedouro - Petrolina - PE Drenagem subterrânea Carga hidráulica Underground drainage systems Irrigated perimeter of Bebedouro - Petrolina - PE Underground drainage Hydraulic load |
???metadata.dc.subject.cnpq???: | Engenharia Agrícola. |
URI: | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39260 |
Appears in Collections: | 26º CONBEA 1997 - Seção Pôster - Engenharia de Água e Solo |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
AVALIAÇÃO DO DESEMPENHO DE SISTEMAS DE DRENAGEM - EVENTO CONBEA UFCG 1997 (1).pdf | Avaliação do desempenho de sistemas de drenagem subterrânea do perímetro irrigado de bebedouro - Petrolina-PE. - Evento Conbea UFCG 1997. | 229.5 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.