Please use this identifier to cite or link to this item:
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39257
Title: | Avaliação do desempenho hidráulico do gotejador Carborundum-GFT. |
Other Titles: | Evaluation of the hydraulic performance of the Carborundum-GFT dripper. |
???metadata.dc.creator???: | MATOS, José de Arimatea de. CRUZ, Raimundo Leite. GOMES, Tamara Maria. |
Keywords: | Gotejador Carborundum - GFT;Carborundum - GFT - gotejador;Desempenho hidráulico;Relação vazão-pressão;Irrigação;Carborundum - GFT dripper;Hydraulic performance;Flow-pressure ratio;Irrigation |
Issue Date: | 1997 |
Publisher: | Universidade Federal de Campina Grande |
Citation: | MATOS, José de Arimatea de; CRUZ, Raimundo Leite; GOMES, Tamara Maria. Avaliação do desempenho hidráulico do gotejador Carborundum-GFT. In: CONGRESSO BRASILEIRO DE ENGENHARIA AGRÍCOLA. Sessão Pôster: Engenharia de Água e Solo. Campina Grande - PB, 26., 1997. Pôster [...]. Campina Grande - PB: Universidade Federal da Paraíba, 1997. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39257 |
???metadata.dc.description.resumo???: | O propósito deste trabalho foi avaliar o desempenho hidráulico do gotejador Carborundum, modelo GFT. Neste sentido foram analisados o coeficiente de variação de fabricação e a equação característica da relação vazão-pressão. O coeficiente de variação de fabricação foi de 0,024, considerado como excelente pela classificação da ASAE. Do ponto de vista estatístico, os dados apresentaram um modelo de distribuição normal. O ajuste dos dados ensaiados de vazão versus pressão, resultou numa equação característica q=0,234*H0,603, com coeficiente de determinação (R2) igual a 0,9976 e regime de fluxo considerado parcialmente turbulento e instável. |
Abstract: | The purpose of this work is to evaluate the GFT model Carborundum hydraulic drip performance. Therefore were analyzed the manufacturing variation coefficient and the characteristic equation of the discharge-pressure relation. The manufacturing variation coefficient was 0.024, which is considered excellent by the ASAE classification. By the statistic point of view, the data showed a normal distribution model. The discharge variation in relation to its average revealed a normal model distribution. The adjustment of the discharge versus pressure tested data resulted in a q=0,234*H0,603 characteristic equation, with a determination coefficient (R2) equals to 0,9976 and the flow regimen was considered partially and unstable. |
Keywords: | Gotejador Carborundum - GFT Carborundum - GFT - gotejador Desempenho hidráulico Relação vazão-pressão Irrigação Carborundum - GFT dripper Hydraulic performance Flow-pressure ratio Irrigation |
???metadata.dc.subject.cnpq???: | Engenharia Agrícola. |
URI: | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39257 |
Appears in Collections: | 26º CONBEA 1997 - Seção Pôster - Engenharia de Água e Solo |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
AVALIAÇÃO DO DESEMPENHO HIDRÁULICO DO GOTEJADOR - EVENTO CONBEA UFCG 1997.pdf | Avaliação do desempenho hidráulico do gotejador Carborundum-GFT. - Evento CONBEA UFCG 1997 | 183.95 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.