Please use this identifier to cite or link to this item:
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39253
Title: | Avaliação de um injetor venturi funcionando para aeração de água. |
Other Titles: | Evaluation of a venturi injector working for water aeration. |
???metadata.dc.creator???: | FEITOSA FILHO, J. Crispiniano. MEDEIROS, J. Francismar de. BOTREL, Tarlei A. PINTO, José Maria. |
Keywords: | Injetor venturi;Aeração de água;Irrigação;Hidráulica;Laboratório de Hidráulica da ESALQ-USP;Venturi injector;Water aeration;Irrigation;Hydraulics;Hydraulics Laboratory of ESALQ-USP |
Issue Date: | 1997 |
Publisher: | Universidade Federal de Campina Grande |
Citation: | FEITOSA FILHO, J. Crispiniano; MEDEIROS, J. Francismar de; BOTREL, Tarlei A; PINTO, José Maria. Avaliação de um injetor venturi funcionando para aeração de água. In: CONGRESSO BRASILEIRO DE ENGENHARIA AGRÍCOLA. Sessão Pôster: Engenharia de Água e Solo. Campina Grande - PB, 26., 1997. Pôster [...]. Campina Grande - PB: Universidade Federal da Paraíba, 1997. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39253 |
???metadata.dc.description.resumo???: | Objetivando avaliar um injetor Venturi para realizar aeração de água, conduziu-se um experimento no Laboratório de Hidráulica da ESALQ-USP com injetor Venturi dotado de câmara de mistura com diâmetros de entrada e saída de 20 mm e diâmetro interno do bocal de 7,1 mm, instalado em série à linha de abastecimento de um sistema de tubos perfurados submersos. Trabalhou-se com pressões de serviço variando de 49,0 até 269,5 kPa, com incrementos de 24,5, produzindo-se, portanto, diferentes vazões motrizes. Mediu-se as vazões succionadas de ar incorporado na água, diferenciais de pressões e rendimento para cada pressão de serviço e definiu-se equações representativas para diferentes relações. Os rendimentos oscilaram entre 5,72 e 9,58% com média de 7,25%, e que a vazão de ar incorporada à água pode ser estimada em função do diferencial de pressão entre a entrada e saída do Venturi por uma relação linear. |
Abstract: | This study was conducted of the Hydraulic Laboratory of University of São Paulo, Piracicaba, Brazil, to determine the performance of injector type Venturi conected in irrigation pipe lines to inject air into the body water for the distribution of oxygen. The injectors were tested by supply pressure of 49,0 to 269,5 kPa, with increment of 24.5 kPa. It was studied variables as: injector head losses; injector discharge suction of air in ten operation pressure and variables flows rates. The major efficiency obtained was 9.58 %. The obtained results permit to establish clarifying tecnical knowledge about the performance on such devices and making possible an appropate choice to their different applications. |
Keywords: | Injetor venturi Aeração de água Irrigação Hidráulica Laboratório de Hidráulica da ESALQ-USP Venturi injector Water aeration Irrigation Hydraulics Hydraulics Laboratory of ESALQ-USP |
???metadata.dc.subject.cnpq???: | Engenharia Agrícola. |
URI: | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39253 |
Appears in Collections: | 26º CONBEA 1997 - Seção Pôster - Engenharia de Água e Solo |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
AVALIAÇÃO DE UM INJETOR VENTURI - EVENTO CONBEA UFCG 1997.pdf | Avaliação de um injetor venturi funcionando para aeração de água. - Evento CONBEA UFCG 1997 | 327.71 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.