Please use this identifier to cite or link to this item:
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39115
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator.ID | LIMEIRA, W.M.J. | pt_BR |
dc.creator.Lattes | http://lattes.cnpq.br/2276328960963278 | pt_BR |
dc.contributor.advisor1 | SOUSA, João Nilton Lopes de. | - |
dc.contributor.advisor1ID | SOUSA, J. N. L. | pt_BR |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/9298652250197069 | pt_BR |
dc.contributor.referee1 | RODRIGUES, Rachel de Queiroz Ferreira. | - |
dc.contributor.referee1ID | RODRIGUES, R. Q. F. | pt_BR |
dc.contributor.referee1Lattes | http://lattes.cnpq.br/3982816841191397 | pt_BR |
dc.contributor.referee2 | SENA, Luana Samara Balduino de. | - |
dc.contributor.referee2Lattes | http://lattes.cnpq.br/4904421917738131 | pt_BR |
dc.description.resumo | A periodontite é uma condição clínica inflamatória causada por biofilme disbiótico que resulta em destruição progressiva da inserção periodontal e pode lavar a perda do dente caso seja tratada. O objetivo deste estudo foi avaliar a eficácia clínica do laser de diodo de alta potência como coadjuvante à instrumentação mecânica em bolsas profundas de um paciente com periodontite, estádio III, grau C e generalizada. Foram examinados 126 sítios, sendo 112 sítios com PS f 3 mm, 8 sítios com PS > 3 mm e < 5 mm, e 6 sítios com PS g 5 mm, onde foram avaliados os parâmetros de profundidade de sondagem (PS), nível de inserção clínica (NIC) e sangramento à sondagem (SS) no início do estudo e após 3 e 6 meses da terapia básica. Todos receberam tratamento periodontal não cirúrgico o que corresponde a raspagem e alisamento coronário radicular (RACR) e polimento coronário. As bolsas periodontais profundas com PS g 5mm, receberam a terapia coadjuvante com luz laser de diodo, com um comprimento de onda de 808 ± 10 nm, potência de 1,5 W, de modo contínuo e entregue por um dispositivo de fibra ótica de 400 μm de diâmetro. Resultados: Houve uma melhora significativa dos parâmetros periodontais de profundidade de sondagem (p < 0,001), perda de inserção clínica (p < 0,001) e sangramento à sondagem (p < 0,001) em todos os sítios tratados. Nos que apresentavam PS g 5 mm, os resultados foram similares, com redução estatisticamente significativa nos valores de profundidade de sondagem (p = 0,006), perda de inserção clínica (p = 0,006) e sangramento à sondagem (p = 0,022), antes e após a realização do tratamento. Após 6 meses, todas as bolsas periodontais com PS g 5mm foram reduzidas a valores menores que 3. Conclusão: A irradiação de bolsas profundas, com laser de diodo de alta potência, mostrou-se eficaz como terapia coadjuvante à raspagem e alisamento coronorradicular em paciente com periodontite estádio III, grau C, generalizada. | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | Centro de Saúde e Tecnologia Rural - CSTR | pt_BR |
dc.publisher.initials | UFCG | pt_BR |
dc.subject.cnpq | Odontologia | pt_BR |
dc.title | Eficácia do laser de diodo de alta potência como coadjuvante à instrumentação mecânica de bolsa profunda em paciente com periodontite estádio III, grau C e generalizada. | pt_BR |
dc.date.issued | 2023-05-31 | - |
dc.description.abstract | Periodontitis is an inflammatory clinical condition caused by a dysbiotic biofilm that results in progressive destruction of the periodontal attachment and can lead to tooth loss if left untreated. The objective of this study was to evaluate the clinical efficacy of high-power diode laser as an adjunct to mechanical instrumentation in deep pockets of a patient with generalized Stage III, Grade C periodontitis. A total of 126 sites were examined, including 112 sites with probing depth (PD) f 3 mm, 8 sites with PD > 3 mm and < 5 mm, and 6 sites with PD g 5 mm. Parameters of probing depth (PD), clinical attachment level (CAL), and bleeding on probing (BOP) were evaluated at baseline, 3 months, and 6 months after basic therapy. All patients received non-surgical periodontal treatment, including scaling and root planing (SRP) and coronal polishing. Deep periodontal pockets with PD g 5 mm received adjunctive therapy with high-power diode laser, using a wavelength of 808 ± 10 nm, power of 1.5 W, continuous mode, and delivered through a 400 μm diameter optical fiber device. Results: There was a significant improvement in periodontal parameters of probing depth (p < 0.001), clinical attachment loss (p < 0.001), and bleeding on probing (p < 0.001) in all treated sites. Similar results were observed in sites with PD g 5 mm, with a statistically significant reduction in probing depth (p = 0.006), clinical attachment loss (p = 0.006), and bleeding on probing (p = 0.022) before and after treatment. After 6 months, all deep periodontal pockets with PD g 5 mm were reduced to values less than 3 mm. Conclusion: Irradiation of deep pockets with high- power diode laser proved to be effective as an adjunctive therapy to scaling and root planing in a patient with generalized Stage III, Grade C periodontitis. | pt_BR |
dc.identifier.uri | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/39115 | - |
dc.date.accessioned | 2024-11-19T11:15:18Z | - |
dc.date.available | 2023-05 | - |
dc.date.available | 2024-11-19T11:15:18Z | - |
dc.type | Trabalho de Conclusão de Curso | pt_BR |
dc.subject | Periodontite | pt_BR |
dc.subject | Raspagem e Alisamento Radicular | pt_BR |
dc.subject | Laser de Alta Potência | pt_BR |
dc.subject | Laser de Diodo | pt_BR |
dc.subject | Periodontitis | pt_BR |
dc.subject | Scaling and Root Planing | pt_BR |
dc.subject | High-Power Laser | pt_BR |
dc.subject | Diode Laser | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.creator | LIMEIRA, Wâne Marquesa Jordão. | - |
dc.publisher | Universidade Federal de Campina Grande | pt_BR |
dc.language | por | pt_BR |
dc.title.alternative | Efficacy of high power diode laser as an adjunct to mechanical instrumentation of a deep pocket in a patient with stage III, grade C and generalized periodontits. | pt_BR |
dc.identifier.citation | LIMEIRA, W.M.J. Eficácia do laser de diodo de alta potência como coadjuvante à instrumentação mecânica de bolsa profunda em paciente com periodontite estádio III, grau c e generalizada. 2023. 70 f. Trabalho de Conclusão de Curso (Odontologia) - Unidade Acadêmica de Ciências Biológicas, Centro de Saúde e Tecnologia Rural, Universidade Federal de Campina Grande, Paraíba, Brasil, 2023. | pt_BR |
Appears in Collections: | Curso de Bacharelado em Odontologia - CSTR - Monografias |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
WÂNE MARQUESA JORDÃO LIMEIRA - MONOGRAFIA (CURSO DE ODONTOLOGIA) 2023.pdf | 5.77 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.