dc.description.resumoA geração distribuída (GD) e o desbalanceamento de carga entre fases são fatores que afetam o nível de perdas técnicas em redes de distribuição, pois alteram a distribuição de corrente na rede e o valor das correntes nos ramais. As mudanças causadas na distribuição ainda são pouco exploradas, apesar de terem impacto direto no cálculo das perdas técnicas e na eficiência operacional. A mensuração do impacto das mudanças pode ser avaliada pela diferença no valor de energia perdida por trecho da rede. Assim, neste trabalho é descrito um procedimento para avaliação das perdas em uma rede de baixa tensão real, que foi utilizada como base para estudos de caso simulados no OpenDSS com diferentes quantidades de unidades de GD e alocação de cargas por fase. De modo a conduzir a análise quantitativa, um fator de concentração foi definido para avaliar a característica da distribuição de GD na rede, bem como um fator de desbalanceamento entre fases. O caso base, sem GD ou desbalanceamento de cargas, tem 10,41 % de perdas técnicas. Os casos de maior agravamento (+3,05%) de perdas corresponderam à alta concentração de GD e de maior diminuição (-1,54%) foram os casos de distribuição mais uniforme da GD. Nos casos estudados, foi possível observar que a GD pode ser agravadora ou mitigadora de perdas técnicas. Em relação ao desbalanceamento de carga, foi constatado aumento gradual do nível das perdas (+0,2%) ainda que para desbalanceamentos maiores que 16% de desbalanceamento de potência entre fases. Para a rede estudada, os resultados das simulações evidenciam que a inserção de GD pode ter maior impacto nas perdas técnicas do que o simples desbalanceamento de carga. A partir de um método de avaliação financeira criado no trabalho, foi possível observar o potencial retorno da gestão de cargas e GD.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Engenharia Elétrica e Informática - CEEIpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia Elétrica.pt_BR
dc.titleUma avaliação de impactos da geração distribuída e do desbalanceamento de carga nas perdas técnicas.pt_BR
dc.date.issued2023-08-07-
dc.description.abstractDistributed generation (DG) and load imbalance between phases are factors that alter technical losses in distribution networks. DG and load imbalance change the current distribution in the network, with a consequent change in the value of the currents in the branches. The changes caused in distribution are still little explored, despite having a direct impact on the calculation of technical losses and operational efficiency. The measurement of impact of the changes can be assessed by the difference in energy lost per section of the network. In this work, a quantitative evaluation of a real low-voltage network was carried out and used as a basis for simulated case studies in OpenDSS with different amounts of DG units and allocation of loads per phase. A concentration factor was defined to evaluate the distribution characteristic of DG in the network, as well as an unbalance factor between phases. The base case, without DG or unbalanced loads, has 10.41% of technical losses. The worst cases (+3.05%) of losses corresponded to the high concentration of DG and the best cases (-1.54%) were the cases of more uniform distribution of DG. In the cases studied, it was possible to observe that DG can be aggravating or mitigating technical losses. Regarding load imbalance, a gradual increase in the level of losses (+0.2%) was observed, even for larger imbalances of 16% between phases. For the studied network, the simulation results show that the insertion of DG can have a greater impact on technical losses than the simple load imbalance. Based on a financial evaluation method created at work, it was possible to observe a potential return on load management and DG.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/38975-
dc.date.accessioned2024-11-12T18:37:20Z-
dc.date.available2024-11-12-
dc.date.available2024-11-12T18:37:20Z-
dc.typeDissertaçãopt_BR
dc.subjectProcessamento de energiapt_BR
dc.subjectGeração distribuídapt_BR
dc.subjectDesbalanceamento de cargapt_BR
dc.subjectPerdas técnicaspt_BR
dc.subjectEnergy processingpt_BR
dc.subjectDistributed generationpt_BR
dc.subjectLoad imbalancept_BR
dc.subjectTechnical lossespt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorOLIVEIRA, Iago Batista.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeAn assessment of the impacts of distributed generation and load imbalance on technical losses.pt_BR
dc.description.sponsorshipCapespt_BR
dc.identifier.citationOLIVEIRA, Iago Batista. Uma avaliação de impactos da geração distribuída e do desbalanceamento de carga nas perdas técnicas. 2024. 69 f. Dissertação (Mestrado em Engenharia Elétrica) – Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande, Paraíba, Brasil, 2023.pt_BR