Please use this identifier to cite or link to this item:
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/32106
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator.ID | COSTA, M. V. P. | pt_BR |
dc.creator.Lattes | http://lattes.cnpq.br/0288922605695695 | pt_BR |
dc.contributor.advisor1 | NETO, José Dantas. | - |
dc.contributor.advisor1ID | DANTAS NETO, J. | pt_BR |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/9137226205129315 | pt_BR |
dc.contributor.advisor2 | LIMA, Vera Lúcia Antunes de. | - |
dc.contributor.advisor2ID | LIMA, V. L. A. | pt_BR |
dc.contributor.advisor2Lattes | http://lattes.cnpq.br/5379077061489077 | pt_BR |
dc.contributor.referee1 | FARIAS, Maria Sallydelândia Sobral de. | - |
dc.contributor.referee2 | FEITOSA, Hernandes de Oliveira. | - |
dc.description.resumo | Em região semiárida o manejo racional da água é essencial para o desenvolvimento da agricultura irrigada. Sendo assim, a presente pesquisa tem por objetivo analisar parâmetros de desempenho hidráulico de unidades gotejadoras irrigadas com água de abastecimento urbano e com água residuária de esgoto doméstico parcialmente tratado, a partir de cartas de controle estatístico de Shewhart. Para tanto, a pesquisa foi desenvolvida na Universidade Federal de Campina Grande (UFCG), em uma área experimental pertencente ao Laboratório de Engenharia de Irrigação e Drenagem (LEID), da Unidade Acadêmica de Engenharia Agrícola (UAEA). Para a realização da pesquisa foram utilizadas unidades gotejadoras avaliadas a cada 24 horas, ao longo de 576 horas de funcionamento, totalizando 25 ensaios, com pressão de serviço de 100 kPa. A cada ensaio foram determinados os parâmetros hidráulicos: Vazão média - Qm, Coeficiente de Uniformidade de Distribuição – CUD e Grau de Entupimento – GE, para dois modelos de fitas gotejadoras irrigadas com água de abastecimento urbano e a água residuária oriunda de esgoto doméstico parcialmente tratado. Dessa maneira, verificou-se que, os parâmetros de desempenho hidráulico (Qm, CUD e GE) das unidades gotejadoras após 576h de irrigação apenas com água proveniente do abastecimento urbano conservaram seus valores entre inaceitáveis e bons para o CUD e o GE baixo médio. Já com água residuária de esgoto doméstico parcialmente tratado, os parâmetros variaram entre inaceitáveis e ruins para o CUD e para o GE alto médio. No que se refere às cartas de controle estatístico de qualidade de Shewhart, houve variações nos processos de irrigação a partir da detecção de mudanças e indícios de falta de controle dos processos. Quanto aos modelos de fitas gotejadoras analisados, o FS apresentou melhor desempenho hidráulico e o FT mais suscetível ao entupimento, com água residuária de esgoto doméstico tratado. Para as características físico-químicos e microbiológicos da água residuária de esgoto doméstico parcialmente tratado, quanto ao risco de entupimento de emissores, os valores foram classificados de “Moderados” a “Severos”. | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | Centro de Tecnologia e Recursos Naturais - CTRN | pt_BR |
dc.publisher.program | PÓS-GRADUAÇÃO EM ENGENHARIA AGRÍCOLA | pt_BR |
dc.publisher.initials | UFCG | pt_BR |
dc.subject.cnpq | Engenharia agrícola. | pt_BR |
dc.title | Cartas de controle estatístico de Shewhart na avaliação de parâmetros hidráulicos de unidades gotejadoras. | pt_BR |
dc.date.issued | 2023-03-23 | - |
dc.description.abstract | In semi-arid region, rational water management is essential for the development of irrigated agriculture. Thus, the present research aims to analyze hydraulic performance parameters of drip units irrigated with urban water supply and partially treated domestic sewage wastewater, from Shewhart statistical control charts. For this purpose, the research was developed at the Federal University of Campina Grande (UFCG), in an experimental area belonging to the Laboratory of Irrigation and Drainage Engineering (LEID), of the Academic Unit of Agricultural Engineering (UAEA). To carry out the research, drip units were evaluated every 24 hours, over 576 hours of operation, totaling 25 tests, with a service pressure of 100 kPa. At each test, the hydraulic parameters were determined: Average Flow - Qm, Distribution Uniformity Coefficient - CUD and Degree of Clogging - GE, for two drip tape models irrigated with urban water supply and wastewater from partially treated domestic sewage. Thus, it was verified that the hydraulic performance parameters (Qm, CUD and GE) of the drip units after 576h of irrigation only with water from the urban supply maintained their values between unacceptable and good for CUD and low medium GE. On the other hand, with partially treated domestic sewage wastewater, the parameters ranged from unacceptable to poor for CUD and medium high GE. Regarding the Shewhart statistical quality control charts, there were variations in the irrigation processes from the detection of changes and indications of lack of process control. As for the drip tape models analyzed, the FS presented better hydraulic performance and the FT more susceptible to clogging, with treated domestic sewage wastewater. For the physicochemical and microbiological characteristics of the partially treated domestic sewage wastewater, regarding the risk of emitter clogging, the values were classified from "Moderate" to "Severe". | pt_BR |
dc.identifier.uri | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/32106 | - |
dc.date.accessioned | 2023-10-17T17:40:28Z | - |
dc.date.available | 2023-10-17 | - |
dc.date.available | 2023-10-17T17:40:28Z | - |
dc.type | Dissertação | pt_BR |
dc.subject | Irrigação | pt_BR |
dc.subject | Água residuária | pt_BR |
dc.subject | Obstrução | pt_BR |
dc.subject | Desempenho hidráulico | pt_BR |
dc.subject | Irrigation | pt_BR |
dc.subject | Wastewater | pt_BR |
dc.subject | Clogging | pt_BR |
dc.subject | Hydraulic performance | pt_BR |
dc.subject | Riego | pt_BR |
dc.subject | Aguas residuales | pt_BR |
dc.subject | Obstrucción | pt_BR |
dc.subject | Rendimiento hidráulico | pt_BR |
dc.subject | Irrigation | pt_BR |
dc.subject | Eaux usées | pt_BR |
dc.subject | Obstruction | pt_BR |
dc.subject | Performance hydraulique | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.creator | COSTA, Maria Viviane Palmeira da. | - |
dc.publisher | Universidade Federal de Campina Grande | pt_BR |
dc.language | por | pt_BR |
dc.title.alternative | Shewhart statistical control charts in the evaluation of hydraulic parameters of dripping units. | pt_BR |
dc.description.sponsorship | Capes | pt_BR |
dc.identifier.citation | COSTA, Maria Viviane Palmeira da. Cartas de controle estatístico de Shewhart na avaliação de parâmetros hidráulicos de unidades gotejadoras. 2023. 67 f. Dissertação (Mestrado em Engenharia Agrícola) – Programa de Pós-Graduação em Engenharia Agrícola, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande, Paraíba, Brasil, 2023. | pt_BR |
Appears in Collections: | Mestrado em Engenharia Agrícola. |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
MARIA VIVIANE PALMEIRA DA COSTA - Dissertação (PPGEA) 2023.pdf | 2.09 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.