Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/31891
Full metadata record
DC FieldValueLanguage
dc.creator.IDSilva, Paulo César Sales dapt_BR
dc.creator.Latteshttp://lattes.cnpq.br/6097353354921674pt_BR
dc.contributor.advisor1Lima, Antonio Gilson Barbosa de-
dc.contributor.advisor1IDBarbosa de Lima, A.G.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4527387699298544pt_BR
dc.contributor.advisor2ARAUJO, Carlos José de.-
dc.contributor.advisor2IDDE ARAÚJO, C. J.pt_BR
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/9466801408291152pt_BR
dc.contributor.referee1GRASSI, Estephanie Nobre Dantas.-
dc.contributor.referee2Castro, Walman Benicio de.-
dc.contributor.referee3OLIVEIRA, Nadja Maria da Silva.-
dc.contributor.referee4Otubo, Jorge.-
dc.description.resumoGrampos ortopédicos de Ligas com Memória de Forma (LMF) do sistema binário Níquel-Titânio (Ni-Ti) Superelásticos (SE) são fixadores metálicos funcionais que possuem a capacidade única de exercer compressão contínua durante a recuperação da forma e compressão dinâmica, alinhando-se aos fatores mecanobiológicos associados à cicatrização óssea. Neste trabalho, foram utilizadas duas ligas de LMF Ni-Ti produzidas pelos processos VIM (Vaccum Induction Melting) e EBM (Electron Beam Melting) para testar a fabricação de protótipos de grampos porosos utilizando a tecnologia de fundição de precisão auxiliada por manufatura aditiva. Os resultados obtidos mostraram que a liga base EBM forneceu a melhor fundidibilidade para obter tais protótipos. Portanto, protótipos produzidos mostraram o comportamento mecânico de superelasticidade à isoterma de 37 °C, apresentando uma redução de até 20% no valor de força máxima, gerada na condição de máxima abertura das hastes, quando comparado a grampos densos. A rigidez secante variou com a temperatura e se situou na faixa entre 13 N/mm e 27,5 N/mm, apresentando uma redução de aproximadamente 14,1 % a 37 °C, quando comparado ao grampo denso. Por fim, foram avaliados a influência de parâmetros geométricos no comportamento mecânico e da distribuição de tensões e fração de martensita. Com isso, observou-se que o ângulo inicial das hastes possui uma maior influência na força gerada e que os poros introduzem concentradores de tensão, elevando assim os níveis de tensões e consequentemente a fração de martensita. Logo, foi possível demonstrar que a tecnologia pode ser utilizada para a obtenção de tais produtos, inclusive com a possibilidade de customização. E que tal tecnologia pode ser estendida para outros dispositivos médico implantáveis, como placas de fixação óssea, pinos e parafusos.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Ciências e Tecnologia - CCTpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA DE PROCESSOSpt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia de Processospt_BR
dc.titleProtótipos de grampos ortopédicos porosos de liga com memória de forma ni-ti: desenvolvimento e caracterização.pt_BR
dc.date.issued2023-02-28-
dc.description.abstractShape Memory Alloy (SMA) orthopaedic staples of the Superelastic (SE) binary system Nickel-Titanium (Ni-Ti) are functional metallic fixators that have the unique ability to exert continuous compression during shape recovery and dynamic compression, aligning due to mechanobiological factors associated with bone healing. In this work, two Ni-Ti SMA alloys produced by VIM (Vaccum Induction Melting) and EBM (Electron Beam Melting) processes were used to test the fabrication of porous staple prototypes using investment casting technology aided by additive manufacturing. The obtained results showed that the EBM alloy provided the best castability to obtain such prototypes. Therefore, prototypes produced showed the mechanical behavior of superelasticity at the isotherm of 37 °C, showing a reduction of up to 20% in the maximum force value, generated in the condition of maximum opening of the legs, when compared to dense staple of Ni-Ti SMA. The secant stiffness varied with the temperature and was in the range between 13 N/mm and 27.5 N/mm, showing a reduction of approximately 14.1% at 37 °C, when compared to the dense staple. Finally, the influence of geometric parameters on the mechanical behavior and on the stress distribution and martensite fraction were evaluated. Thus, it was observed that the initial angle of the legs has a greater influence on the generated force and that the pores introduce stress concentrators, thus increasing the stress levels and consequently the martensite fraction. Therefore, it was possible to demonstrate that the technology can be used to obtain such products, including the possibility of customization. And that such technology can be extended to other implantable medical devices, such as bone fixation plates, pins and screws.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/31891-
dc.date.accessioned2023-10-09T19:22:44Z-
dc.date.available2023-10-09-
dc.date.available2023-10-09T19:22:44Z-
dc.typeTesept_BR
dc.subjectLigas com memória de formapt_BR
dc.subjectLigas Ni-Tipt_BR
dc.subjectEstruturas porosaspt_BR
dc.subjectAnálise por elementos finitospt_BR
dc.subjectGrampos ortopédicospt_BR
dc.subjectShape memory alloyspt_BR
dc.subjectNi-Ti alloyspt_BR
dc.subjectBone staplept_BR
dc.subjectPorous structurespt_BR
dc.subjectFinite element analysispt_BR
dc.subjectAlliages à mémoire de formept_BR
dc.subjectAlliages Ni-Tipt_BR
dc.subjectPinces orthopédiquespt_BR
dc.subjectStructures poreusespt_BR
dc.subjectAnalyse par éléments finispt_BR
dc.subjectAleaciones con memoria de formapt_BR
dc.subjectAleaciones de Ni-Tipt_BR
dc.subjectAbrazaderas ortopédicaspt_BR
dc.subjectEstructuras porosaspt_BR
dc.subjectAnálisis de elementos finitospt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorSILVA, Paulo César Sales da.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativePrototypes of porous alloy orthopedic clamps with ni-ti shape memory: development and characterization.pt_BR
dc.description.sponsorshipCNPqpt_BR
dc.relationCapespt_BR
dc.identifier.citationSILVA, Paulo César Sales da. Protótipos de grampos ortopédicos porosos de liga com memória de forma ni-ti: desenvolvimento e caracterização. 2023. 135 f. Tese (Doutorado em Engenharia de Processos) – Programa de Pós-Graduação em Engenharia de Processos, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande, Paraíba, Brasil, 2023.pt_BR
Appears in Collections:Doutorado em Engenharia de Processos.

Files in This Item:
File Description SizeFormat 
PAULO CÉSAR SALES DA SILVA – TESE (PPGEP) 2023.pdf5.93 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.