Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/28076
Full metadata record
DC FieldValueLanguage
dc.creator.IDCUNHA, G. C. A.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/6749829919471640pt_BR
dc.contributor.advisor1LOPES NETO, José Pinheiro.-
dc.contributor.advisor1IDLOPES NETO, J. P.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1800101850675185pt_BR
dc.contributor.referee1FREIRE, Elias Antonio.-
dc.contributor.referee1IDFREIRE, E. A.pt_BR
dc.contributor.referee1Latteshttp://lattes.cnpq.br/4090558218076955pt_BR
dc.contributor.referee2NASCIMENTO, José Wallace Barbosa do.-
dc.contributor.referee2IDNASCIMENTO, J. W. B.pt_BR
dc.contributor.referee2Latteshttp://lattes.cnpq.br/9274991135144621pt_BR
dc.contributor.referee3FURTADO, Dermeval Araújo.-
dc.contributor.referee3IDFURTADO, D. A.pt_BR
dc.contributor.referee4PEREIRA, Valéria Peixoto Borges.-
dc.contributor.referee4IDPEREIRA, V. P. Bpt_BR
dc.description.resumoNo Brasil, o emprego de sistemas de condicionamento artificial em pressão negativa em galpões avícolas está se tornando cada vez mais comum e, na Paraíba, ainda que a passos mais lentos, vem sendo incorporado por viabilizar a correção do microclima no interior de aviários. No entanto, pesquisas desenvolvidas na área de Construções Rurais e Ambiência apontam para a necessidade de melhoria da eficiência desses sistemas vez que identificam a distribuição heterogênea do ar ao longo das instalações e a inadequação dos dados ambientais internos às faixas recomendadas para o conforto térmico de aves adultas, especialmente nos períodos mais quentes do dia. Diante do exposto, avaliou-se a eficiência de diferentes arranjos construtivos de aviários para frangos de corte, ventilados à pressão negativa, por meio da análise da distribuição da temperatura do ar (Tar), umidade relativa (UR) e velocidade do vento (Vv) e da caracterização do ambiente térmico em função do Índice de temperatura, umidade e velocidade do ar (ITUV). Para tanto, instrumentou-se um galpão para coleta de dados de campo e diagnóstico de suas instalações quanto ao conforto térmico interno; gerou-se um modelo computacional de referência baseado neste galpão, por meio do software Autodesk CFD 2016; validou-se esse modelo; testaram-se três diferentes arranjos de coberta (TiFiA- baseado no protótipo, com forro paralelo à cobertura inclinada e aletas, TiFisA- semelhante à TiFiA, excluindo-se as aletas e TiFh- similar à TiFisA, com forro horizontal); selecionou-se aquele mais eficiente e combinou-se à dois arranjos de painéis evaporativos (TiFisA20L e TiFisA40L, com 20% e 40% da área dos painéis voltadas à Leste, respectivamente). Concluiu-se que: segundo ITUV, o galpão instrumentado, entre 12 e 14 h, não proveu conforto às aves adultas alojadas, com valores de Tar, UR e Vv não pertinentes às faixas recomendadas; o modelo CFD para TiFisA foi validado com médias de Tar coletadas em campo de 27,75 ± 1,35 oC e simuladas de 27,85 ± 0,55 oC, médias de UR coletadas de 83% ± 12% e simuladas de 78% ± 3% e médias das Vv coletadas de 2,35 ± 1,35 m.s-1 e simuladas de 2,50 ± 1,50 m.s-1; dentre os tratamentos de coberta testados, TiFisA mostrou ser o mais adequado ao conforto das aves em função do padrão de distribuição da Tar e da Vv; e dentre todos os arranjos simulados, TiFisA mostrou ser o mais adequado ao conforto das aves em função do padrão de distribuição da Tar.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Tecnologia e Recursos Naturais - CTRNpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA AGRÍCOLApt_BR
dc.publisher.initialsUFCGpt_BR
dc.subject.cnpqEngenharia de Agrícolapt_BR
dc.titleModelagem computacional da distribuição de variáveis ambientais em aviário ventilado à pressão negativa.pt_BR
dc.date.issued2017-02-
dc.description.abstractIn Brazil, the use of artificial conditioning systems in negative pressure in poultry houses is becoming increasingly common and in Paraiba, although at a slower pace, has been incorporated for making possible the correction of the microclimate inside aviaries. However, researches developed in the area of Rural Constructions and Ambience indicate the need to improve the efficiency of these systems instead of identifying the heterogeneous distribution of air throughout the building and the inadequacy of internal environmental data to the recommended ranges for the thermal comfort of broilers especially in the hottest times of the day. For these reasons, the efficiency of different constructive arrangements was evaluated in broilers houses, ventilated at negative pressure, by analyzing the distribution of air temperature (Tar), relative humidity (UR) and wind speed (Vv) and characterization of the thermal environment using the Temperature, Humidity and Air Velocity Index (ITUV). For that, a poultry house was instrumented for field data collection and diagnosis of its internal thermal comfort facilities; a computer model of reference was generated based on this aviary, using the software Autodesk CFD 2016; this model was validated; Three different cover arrangements (TiFiA- based on the prototype, with ceiling parallel to the inclined cover and fins, TiFisA- similar to TiFiA, excluding fins and TiFh- similar to TiFisA, with horizontal ceiling) were tested; the most efficient cover arrangement was selected and combined with two evaporative panel arrangements (TiFisA20L and TiFisA40L, with 20% and 40% of the area of the panels facing the East, respectively). It was concluded that: according to ITUV, the instrumented aviary, between 12 and 14 h, did not provide comfort to the adult poultrys housed, with Tar, UR and Vv values not pertinent to the recommended ranges; the CFD model for TiFisA was validated with Tar averages of 27.75 ± 1.35 oC collected in the field and simulated ones were 27.85 ± 0.55 oC, UR mean values of 83% ± 12% collected and simulated ones of 78% ± 3% and Vv means values of 2.35 ± 1.35 m.s-1 collected and simulated ones were of 2.50 ± 1.50 m.s-1; among the tested cover treatments, TiFisA showed to be the most adequate to the comfort of the broilers according to the distribution pattern of Tar and Vv; and among all the simulated arrangements, TiFisA was shown to be the most suitable for the comfort of the broilers according to the Tar distribution pattern.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/28076-
dc.date.accessioned2022-11-29T12:32:25Z-
dc.date.available2022-11-29-
dc.date.available2022-11-29T12:32:25Z-
dc.typeTesept_BR
dc.subjectAviário ventilado à pressão negativapt_BR
dc.subjectNegative pressure ventilated poultry housept_BR
dc.subjectConstruções rurais e ambiênciapt_BR
dc.subjectRural buildings and ambiencept_BR
dc.subjectModelagem computacionalpt_BR
dc.subjectComputational modelingpt_BR
dc.subjectVariáveis ambientais - aviáriopt_BR
dc.subjectEnvironmental variables - aviarypt_BR
dc.subjectBioclimatologiapt_BR
dc.subjectBioclimatologypt_BR
dc.subjectConforto térmicopt_BR
dc.subjectThermal comfortpt_BR
dc.subjectInstalações avícolas - ambiênciapt_BR
dc.subjectPoultry facilities - ambiencept_BR
dc.subjectAmbiência nas instalações avícolaspt_BR
dc.subjectAmbience in poultry facilitiespt_BR
dc.subjectFisiologia da avept_BR
dc.subjectBird physiologypt_BR
dc.subjectSensores de ventopt_BR
dc.subjectWind sensorspt_BR
dc.subjectSimulações CFDpt_BR
dc.subjectCFD simulationspt_BR
dc.subjectArranjos construtivospt_BR
dc.subjectConstructive arrangementspt_BR
dc.subjectValidação de modelospt_BR
dc.subjectModel validationpt_BR
dc.subjectAvicultura - ambiênciapt_BR
dc.subjectPoultry - ambiencept_BR
dc.rightsAcesso Abertopt_BR
dc.creatorCUNHA, Gisele Caldas de Araújo.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeComputational modeling of the distribution of environmental variables in negative pressure ventilated aviary.pt_BR
dc.identifier.citationCUNHA, Gisele Caldas de Araújo. Modelagem computacional da distribuição de variáveis ambientais em aviário ventilado à pressão negativa. 2017. 133f. (Tese de Doutorado) Programa de Pós-Graduação em Engenharia Agrícola, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande - Paraíba - Brasil, 2017. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/28076pt_BR
Appears in Collections:Doutorado em Engenharia Agrícola.

Files in This Item:
File Description SizeFormat 
GISELE CALDAS DE ARAÚJO CUNHA - TESE PPGEA CTRN 2017.pdfGisele Caldas de Araújo Cunha - Tese PPGEA CTRN 20176.99 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.