Please use this identifier to cite or link to this item:
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/26987
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator.ID | DINIZ, L. | pt_BR |
dc.creator.Lattes | http://lattes.cnpq.br/0970506061860633 | pt_BR |
dc.contributor.advisor1 | COSTA, Edson Guedes da. | - |
dc.contributor.advisor1ID | COSTA, E. G. | pt_BR |
dc.contributor.advisor1ID | COSTA, EDSON G. | pt_BR |
dc.contributor.advisor1ID | COSTA, E.G. DA. | pt_BR |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/3930289115658143 | pt_BR |
dc.contributor.advisor2 | FERREIRA, Tarso Vilela. | - |
dc.contributor.advisor2ID | FERREIRA, T. V. | pt_BR |
dc.contributor.advisor2ID | FERREIRA, TARSO V. | pt_BR |
dc.contributor.advisor2ID | FERREIRA, TARSO. | pt_BR |
dc.contributor.advisor2Lattes | http://lattes.cnpq.br/9395719025602516 | pt_BR |
dc.contributor.referee1 | FREIRE, Raimundo Carlos Silvério. | - |
dc.contributor.referee1ID | FREIRE, R. C. S. | pt_BR |
dc.contributor.referee1ID | FREIRE, R. | pt_BR |
dc.contributor.referee1ID | Freire, Raimundo C. S. | pt_BR |
dc.contributor.referee1Lattes | http://lattes.cnpq.br/4016576596215504 | pt_BR |
dc.contributor.referee2 | GERMANO, André Dantas. | - |
dc.contributor.referee2ID | GERMANO, A. D. | pt_BR |
dc.contributor.referee2ID | GERMANO, André Dantas. | pt_BR |
dc.contributor.referee2ID | Germano, André D. | pt_BR |
dc.contributor.referee2Lattes | http://lattes.cnpq.br/5861671113603396 | pt_BR |
dc.description.resumo | Este trabalho apresenta uma investigação da correlação entre temperatura e campo elétrico para o aprimoramento da inspeção de isoladores poliméricos. Amostras de isoladores poliméricos de 138 kV, íntegras e com defeitos, foram submetidos a ensaios elétricos e medições termográficas. Isoladores retirados do campo foram submetidos a ensaios em sete níveis de tensão aplicada e as medições termográficas foram realizadas após o equilíbrio térmico ser estabelecido. Os isoladores poliméricos foram modelados e simulações computacionais de campo elétrico foram realizadas nas regiões de interesse. Os resultados das medições termográficas, realizadas durante os ensaios, mostraram elevações de temperatura maiores na região próxima ao terminal fase, quando os defeitos estão presentes. Os resultados das simulações computacionais dos isoladores sem defeitos externos não apresentaram distorções de campo elétrico. A análise dos isoladores com defeitos mostrou que o campo elétrico sofre distorções e sua intensidade depende da configuração do defeito e da posição dos defeitos, corroborando com as medições de temperatura. Os resultados indicam que existe uma tendência de crescimento da temperatura nos pontos onde o campo elétrico é mais intenso (furos superficiais). | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | Centro de Engenharia Elétrica e Informática - CEEI | pt_BR |
dc.publisher.program | PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA | pt_BR |
dc.publisher.initials | UFCG | pt_BR |
dc.subject.cnpq | Engenharia Elétrica | pt_BR |
dc.title | Aprimoramento da inspeção visual de isoladores poliméricos por termografia e campo elétrico. | pt_BR |
dc.date.issued | 2019-03-25 | - |
dc.description.abstract | This work presents an evaluation of the correlation between temperature and electric field to the improvement of polymeric insulators inspection. Samples of 138 kV polymeric insulators, intact and defectives, were submitted to electrical tests and thermographic measurements. Thus, the insulators removed from transmission lines were submitted to seven level of applied voltage and the thermographic measurements were realized once thermal equilibrium was established. The polymeric insulators were modeled and computational simulations of electric field were performed in the regions of interest. The results of the thermographic measurements, performed during the tests, showed higher temperature increases near the phase, when the defects are present. The results of the computational simulations of the insulators without external defects showed no electric field distortions. The analysis of defective insulators revealed that the electric field is distorted and its intensity depends on the defects’ configuration and position, corroborating with the temperature measurements. The results indicate the existence of a growth trend of the temperature at the points where the electrical field is more intense (superficial holes). | pt_BR |
dc.identifier.uri | http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/26987 | - |
dc.date.accessioned | 2022-09-06T20:04:13Z | - |
dc.date.available | 2022-09-06 | - |
dc.date.available | 2022-09-06T20:04:13Z | - |
dc.type | Dissertação | pt_BR |
dc.subject | Isoladores poliméricos | pt_BR |
dc.subject | Termografia | pt_BR |
dc.subject | Cálculo de campo elétrico | pt_BR |
dc.subject | Inspeções termográficas | pt_BR |
dc.subject | Inspeção visual | pt_BR |
dc.subject | Processamento de Energia | pt_BR |
dc.subject | Polymeric insulators | pt_BR |
dc.subject | Thermography | pt_BR |
dc.subject | Electric field calculation | pt_BR |
dc.subject | Thermographic inspections | pt_BR |
dc.subject | Visual inspection | pt_BR |
dc.subject | Energy Processing | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.creator | DINIZ, Larissa. | - |
dc.publisher | Universidade Federal de Campina Grande | pt_BR |
dc.language | por | pt_BR |
dc.title.alternative | Improvement of visual inspection of polymeric insulators by thermography and electric field. | pt_BR |
dc.identifier.citation | DINIZ, Larissa. Aprimoramento da inspeção visual de isoladores poliméricos por termografia e campo elétrico. 2019. 99 fl. Dissertação (Mestrado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2019. | pt_BR |
Appears in Collections: | Mestrado em Engenharia Elétrica. |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
LARISSA DINIZ - DISSERTAÇÃO (PPGEE) 2019.pdf | Larissa Diniz - Dissertação (PPGEE) 2019. | 2.6 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.