Title: Avaliação microbiológica em equipamentos de aerossolterapia hospitalar.
Other Titles: Microbiological evaluation in hospital aerosol therapy equipment.
Evaluación microbiológica de equipos hospitalarios de aerosolterapia.
???metadata.dc.creator???: SILVA NETO, Firmino Marcelino da.
???metadata.dc.contributor.advisor1???: CARMO, Egberto Santos.
???metadata.dc.contributor.referee1???: LEON, Carlos Márcio Moura Ponce de.
???metadata.dc.contributor.referee2???: MARQUES, Michael Radan de Vasconcelos.
Keywords: Nebulizadores;Hospitalar;Microbiologia;Nebulizers;Hospital;Microbiology
Issue Date: 28-Nov-2019
Publisher: Universidade Federal de Campina Grande
Citation: SILVA NETO,Firmino Marcelino da. Avaliação microbiológica em equipamentos de aerossolterapia hospitalar. 2019. 39 fl. (Trabalho de Conclusão de Curso – Monografia), Curso de Bacharelado em Farmácia, Centro de Educação e Saúde, Universidade Federal de Campina Grande, Cuité – Paraíba – Brasil, 2019.
???metadata.dc.description.resumo???: Existe uma considerável demanda no uso de nebulizadores no ambiente hospitalar, para tratar afecções diversas relacionadas ao trato respiratório. Este estudo objetiva avaliar a contaminação microbiológica de nebulizadores disponíveis para utilização imediata por pacientes e ainda fazer uma breve associação da contaminação do nebulizador com os métodos de reprocessamento. Metodologia: Foram coletadas amostras de nebulizadores (máscara e copo reservatório), com um swab umedecido em solução salina e semeados em meios de cultura seletivos para bactérias e fungos, passado o período de incubação, para as amostras que demonstraram positividade foram feitas analises de identificação e diferenciação. Foi feita ainda uma análise dos protocolos de reprocessamento das unidades de saúde. Resultados: 40% das amostras analisadas apresentaram contaminação por algum tipo de microrganismo, Enterobacter spp., Bacilos gram positivo e Staphylococcus coagulase negativo foram os espécimes encontrados nesse estudo. Conclusão: No presente estudo, pode-se concluir que há uma fragilidade no reprocessamento desses equipamentos, essas falhas provavelmente acarretam um produto final com pouca confiabilidade do ponto de vista da desinfecção, não oferecendo, consequentemente, segurança ao usuário.
Abstract: There is considerable demand for the use of nebulizers in the hospital environment to treat various respiratory tract-related conditions. This study aims to evaluate the microbiological contamination of nebulizers available for immediate use by patients and to make a brief association of nebulizer contamination with reprocessing methods. Methodology: Samples of nebulizers (mask and reservoir cup) were collected, with a swab moistened with saline solution and sown in culture media selective for bacteria and fungi, after the incubation period. and differentiation. An analysis of the reprocessing protocols of the health units was also made. Results: 40% of the analyzed samples presented contamination by some type of microorganism, Enterobacter spp., Gram positive bacilli and coagulase negative Staphylococcus were the specimens found in this study. Conclusion: In the present study, it can be concluded that there is a fragility in the reprocessing of these articles, these failures probably lead to a final product with little reliability from the point of view of disinfection, thus not offering safety to the user.
???metadata.dc.description.resumen???: Existe una demanda considerable del uso de nebulizadores en el ámbito hospitalario para tratar diferentes afecciones relacionadas con las vías respiratorias. Este estudio tiene como objetivo evaluar la contaminación microbiológica de los nebulizadores disponibles para uso inmediato por parte de los pacientes y también hacer una breve asociación de la contaminación del nebulizador con los métodos de reprocesamiento. Metodología: Se tomaron muestras de nebulizadores (mascarilla y vaso reservorio), con hisopo humedecido en solución salina y sembrado en medios de cultivo selectivos para bacterias y hongos, luego del periodo de incubación, para las muestras que presentaron positividad se realizaron análisis de identificación y diferenciación. También se realizó un análisis de los protocolos de reprocesamiento de las unidades de salud. Resultados: El 40% de las muestras analizadas presentaron contaminación por algún tipo de microorganismo, Enterobacter spp., bacilos Gram positivos y Staphylococcus coagulasa negativos fueron los especímenes encontrados en este estudio. Conclusión: En el presente estudio se puede concluir que existe una debilidad en el reprocesamiento de estos equipos, estas fallas probablemente den lugar a un producto final con poca confiabilidad desde el punto de vista de la desinfección, por lo que no ofrece seguridad al usuario.
Keywords: Nebulizadores
Hospitalar
Microbiologia
Nebulizers
Hospital
Microbiology
???metadata.dc.subject.cnpq???: Microbiologia Aplicada
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/12049
Appears in Collections:Curso de Bacharelado em Farmácia - CES - Monografias

Files in This Item:
File Description SizeFormat 
FIRMINO MARCELINO DA SILVA NETO - TCC BACHARELADO EM FARMÁCIA CES 2019.pdfFirmino Marcelino da Silva Neto - TCC Bacharelado em Farmácia CES 2019 944.11 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.