Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11498
Full metadata record
DC FieldValueLanguage
dc.creator.IDSOARES, J. M.pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/6754008183460303pt_BR
dc.contributor.advisor1BEZERRA, Raimundo Leidimar.-
dc.contributor.advisor1IDBEZERRA, R. L.pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1046305389288490pt_BR
dc.contributor.advisor2CONCIANI, Wilson.-
dc.contributor.advisor2IDCONCIANI, W.-
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/7963414625844731-
dc.contributor.referee1CARVALHO, João Batista Queiroz de.-
dc.contributor.referee2BELICANTA, Antônio.-
dc.description.resumo0 surgimento da ideia de complementar o SPT tradicional com medida de torque foi proposta inicialmente por Ranzini (1988), porem apenas em 1991 em São Paulo, e que foram executados os primeiros SPT-T (Decourt e Quaresma Filho, 1991). Na região nordeste, o SPT-T foi executado algumas vezes, porem, nenhuma pesquisa foi desenvolvida a respeito deste ensaio. A presente pesquisa utiliza o SPT-T com o objetivo de avaliar a sua operacionalidade e a obtenção de parâmetros de projeto de fundações, de forma a dar início a formação de um banco de dados. Paralelamente, foram também executados ensaios pressiométricos (PMT) para determinação de parâmetros de resistência e deformabilidade. Com os dados de ambos ensaios, procurou-se correlaciona-los de forma a aproveitar as potencialidades inerentes a cada ensaio. A campanha de ensaios foi realizada em um deposito arenoso do litoral de João Pessoa - PB, o qual foi submetido a um melhoramento com emprego de estacas de areia e brita, com vistas a substituir o uso de fundações profundas por fundações superficiais. Esta técnica de melhoramento na região nordeste tem sido empregada, principalmente, nos litorais de João Pessoa e Recife. De umas maneira geral, verificou-se que ambos ensaios utilizados forneceram parâmetros que indicam a influência do melhoramento do solo, tendo-se em vista que os resultados obtidos após o melhoramento foram superiores aos encontrados em outros depósitos próximos ao estudado. Os parâmetros obtidos pelo SPT-T e PMT não se correlacionaram satisfatoriamente, em virtude disto torna-se necessário fazer novos estudos para confirmar se o responsável por este fato e a perturbação a que o solo foi submetido durante a cravação das estacas de areia e brita.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro de Tecnologia e Recursos Naturais - CTRNpt_BR
dc.publisher.programPÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTALpt_BR
dc.publisher.initialsUFCGpt_BR
dc.titleEmprego do SPT-T e pressiômetro Ménard em um depósito arenoso da região litorânea de João Pessoa.pt_BR
dc.date.issued1999-08-
dc.description.abstractThe idea of complementing traditional SPT with torque measurement was initially proposed by Ranzini (1988) however only in 1991 it was used in Sao Paulo state (Decourt and Quaresma Filho, 1991). On ther other hand, in the north-east of Brazil, SPT-T was used rarely from the practical point of view but without any research data avaiable. The present research used SPT-T with the main objectives of evaluating its performance and obtaining parameters for foundation design aiming to a database formation. In the same time, Menard pressuremeter tests (PMT) will be carried out for the determination of strength and deformation parameters. The results obtained will be used for a correlation statical analysis. The campain of tests was accomplished in a sand deposit located in the coast of Joao Pessoa (Paraiba state). This deposit was first submitted to a locally and normally used improvement by placing sand and gravel piles with the objective of replacing deed foundation by shallow foundation. In a general way, it was observed that the use of existing parameters indicated the positive influence of the improvement of the sandy deposit. Also, the results showed that after the improvement the parameters obtained by SPT-T and PMT were not satisfactorily correlated. Due to this fact it is necessary to analyze what cause the lack of satisfactory correlation, which seems to be caused by the disturbance due to the driven of the sand and gravel piles.pt_BR
dc.identifier.urihttp://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11498-
dc.date.accessioned2020-02-04T15:41:42Z-
dc.date.available2020-02-04-
dc.date.available2020-02-04T15:41:42Z-
dc.typeDissertaçãopt_BR
dc.rightsAcesso Abertopt_BR
dc.creatorSOARES, José Moura.-
dc.publisherUniversidade Federal de Campina Grandept_BR
dc.languageporpt_BR
dc.title.alternativeUse of SPT-T and Ménard pressure gauge in a sandy deposit in the coastal region of João Pessoa.pt_BR
dc.identifier.citationSOARES, José Moura. Emprego do SPT-T e pressiômetro Ménard em um depósito arenoso da região litorânea de João Pessoa. 115f. (Dissertação de Mestrado em Engenharia Civil e Ambiental), Curso de Pós-Graduação em Engenharia Civil, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba – Campus II - Campina Grande - PB - Brasil,1999. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/11498pt_BR
Appears in Collections:Mestrado em Engenharia Civil e Ambiental.

Files in This Item:
File Description SizeFormat 
JOSÉ MOURA SOARES - DISSERTAÇÃO PPGEC 1999.pdfJosé Moura Soares - Dissertação PPGEC 1999. 10.81 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.