Please use this identifier to cite or link to this item: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10510
Title: Caracterização hidráulica do tape santeno.
Other Titles: Hydraulic characterization of the santeno tape.
???metadata.dc.creator???: MARINHO, Albanise Barbosa.
???metadata.dc.contributor.advisor1???: DANTAS NETO, José.
???metadata.dc.contributor.advisor2???: AZEVEDO, Hamilton Medeiros de.
???metadata.dc.contributor.referee1???: AZEVEDO, Carlos Alberto Vieira de.
???metadata.dc.contributor.referee2???: GOMES, Heber Pimentel.
???metadata.dc.contributor.referee3???: SOUSA, José Luiz de.
Keywords: Irrigação Hidráulica;Tape Santeno;Avaliação Hidráulica;Tape Santeno-Avaliação dos Orificios;Tape Santeno-Altura e Alcance de Jato;Tape Santeno-Diâmetro Interno;Tape Santeno-Pressão de Ruptura;Hydraulic Irrigation;Tape Santeno;Hydraulic Evaluation;Tape Santeno-Evaluation of the Orifices;Tape Santeno-Height and Jet Range;Santeno-Internal Diameter Tape;Tape Santeno-Burst Pressure
Issue Date: 18-Mar-1999
Publisher: Universidade Federal de Campina Grande
Citation: MARINHO, Albanise Barbosa. Caracterização hidráulica do tape santeno. 1999. 92f. (Dissertação) Mestrado em Engenharia Agrícola, Programa de Pós-Graduação em Engenharia Agrícola, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba - Campus II - Campina Grande - Paraíba - Brasil, 1999. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10510
???metadata.dc.description.resumo???: O presente trabalho teve como objetivo estudar a performance hidráulica do Tape SANTENO, que trata-se de um tubo perfurado flexível de polietileno linear de baixa densidade, com orifícios feitos a raio laser. Os Tapes SANTENO utilizados, apresentam diâmetro nominal de 28 mm, diâmetro dos orifícios de 0,3 mm, com dois pares de orifícios espaçados em 1,20 metros, os quais operam com pressões de serviço de 20 a 80 kPa Foram analisados os seguintes aspectos hidráulicos: equação característica da relação vazão-pressão; coeficiente de variação de fabricação dos orifícios; coeficiente de uniformidade de vazão ao longo das linhas laterais, coeficiente de descarga dos orifícios, diâmetros internos do tubo variando a pressão; alcance e altura do jato d'água; vazão em função do comprimento de linha lateral; comprimentos máximos da lateral de acordo com critérios preestabelecidos de variação de vazão; e perda de carga ao longo da tubulação, utilizando-se as equações de Flamant, Darey-WeisbacH e Hazen-Williams. A relação vazão versus pressão foi ajustada a uma equação potencial, com coeficiente de determinação ( r ) igual a 99,91%. 0 coeficiente de variação de fabricação médio para as quatro pressões testadas foi de 4,10%, considerado como excelente pela norma americana ASAE. Os coeficientes de descarga médios obtidos para os orifícios foram de 0,70, 0,69, 0,69 e 0,70, respectivamente para as pressões de 20, 40. 60 e 80 kPa. Os coeficientes de uniformidade de vazão apresentaram valores superiores a 96%. Os alcances do jato d'água foram de 1,30 e 2,50 metros para o tape SANTENO 1 e de 1,70 e 3,00 metros para o tape SANTENO I I , operando-se nas pressões de 20 e 80 kPa. Os diâmetros internos variaram de 27,82 a 29,02 mm quando a pressão variou de 20 a 80 kPa. A pressão de ruptura da parede, do tubo foi de 169,30 kPa. A vazão em função do comprimento variou de 11,25 a 7,09 1/h/m, dados obtidos experimentalmente para comprimentos de 10 a 200 metros e pressão de 80 kPa. Os comprimentos máximos das linhas laterais, calculados de acordo com os critérios de variação de vazão de 10. 15 e 20%, foram 156,0, 182,40 e 204.0m, respectivamente. O tape SANTENO apresentou baixos valores perda de carga ao longo da linha lateral, onde os resultados obtidos pelas equações de Flamant e de Darcy-Weisbach foram bastante próximos, já a equação de Hazen-Williams gerou valores inferiores aos dessas outras equações.
Abstract: The objective of this research was to study the hydraulic performance of the SANTENO tape, which is a perforated flexible polyethylene linear pipe o f low density, with orifices made by laser radius. The SANTENO tapes used have a 28 mm commercial diameter, diameter of the orifices equal to 0.3 mm. with two pairs of orifices equally spaced in 1.2 meters. The orifices operate with pressures from 20 to 80 kPa. That were evaluated the following hydraulic aspects: characteristic equation of the discharge and pressure relationship; manufacturing variation coefficient of the orifices, discharge uniformity coefficient along the lateral lines; orifice discharge coefficient; pipe inner diameters varying the pressure, reach and height of the water jet; discharge as a function of the pipe length; maximum pipe lengths according to criteria previously established for discharge variations; and head loss along the pipe, using the equations of Flamant, Darcy- Weisbach and Hazen-Williams. the relationship between discharge and pressure was given by a power function, with a determination coefficient ( r ) equal to 99.91%. For the four tested pressures, the average manufacturing variation coefficient was 4.1%, which is considered excellent by the ASAE standard. The average discharge coefficients obtained for the orifices were 0.70, 0.69, and 0.70, respectively, for pressures equal to 20. 40, 60 and 80 kPa. The discharge uniformity coefficients presented values higher than 96%. The water jet reaches were 1.3 and 2.5 meters for the SANTENO tape 1 and 1.7 and 3.0 meters for the SANTENO tape 11, operating with pressures equal to 20 and 80 kPa. The inner diameters varied from 27.82 to 29.02 mm for a pressure change from 20 to 80 kPa. The pipe wa|£breakage pressure was 169.3 kPa. The discharge as a function of the pipe length varied from 11.25 to 7.09 1/h/m, data obtained experimentally for lengths from 10 to 200 meters and pressure equal to 80 kPa. The maximum lengths of the lateral lines, calculated according to the discharge variation criteria equal to 10, 15 and 20%, were 156.0, 182.4 and 204.0 meters, respectively. The SANTENO tape presented low values ofjiead loss along the pipe, where the results given by the Darcy-Weisbach and Flamant equations were very close; however, Hazen-W;illiams equation presented values inferior to the ones given by these others equations.
Keywords: Irrigação Hidráulica
Tape Santeno
Avaliação Hidráulica
Tape Santeno-Avaliação dos Orificios
Tape Santeno-Altura e Alcance de Jato
Tape Santeno-Diâmetro Interno
Tape Santeno-Pressão de Ruptura
Hydraulic Irrigation
Tape Santeno
Hydraulic Evaluation
Tape Santeno-Evaluation of the Orifices
Tape Santeno-Height and Jet Range
Santeno-Internal Diameter Tape
Tape Santeno-Burst Pressure
???metadata.dc.subject.cnpq???: Engenharia Agrícola
URI: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/10510
Appears in Collections:Mestrado em Engenharia Agrícola.

Files in This Item:
File Description SizeFormat 
ALBANISE BARBOSA MARINHO - DISSERTAÇÃO PPGEA 1999.pdfAlbanise Barbosa Marinho - Dissertação PPGEA 1999.2.03 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.